期刊文献+

抗重金属Cr^(3+)单克隆抗体的制备及其应用 被引量:6

Preparation and application of monoclonal antibodies against Heavy Metal Chromium
下载PDF
导出
摘要 目的:制备重金属Cr3+的单克隆抗体(mAb)并建立间接竞争ELISA法,用于Cr3+的检测。方法:用合成的重金属铬-螯合剂-BSA抗原免疫BALB/c小鼠,通过细胞融合、克隆化和ELISA等技术建立杂交瘤细胞株;腹水型mAb经硫酸铵沉淀纯化后建立间接竞争ELISA法并与9种金属进行交叉实验;水样加标后,进行间接竞争ELISA法与ICP-AES法检测Cr3+的比较,计算两种方法符合率。结果:获得3株稳定分泌抗重金属Cr3+mAb的杂交瘤细胞株,其中5G12C5株mAb间接ELISA效价>1∶1×105,间接竞争ELISA法检测Cr3+的范围为0.783~50μg/L,最低检测限为1μg/L,与Fe3+存在<10%交叉,而与其他金属无交叉反应;当水样中加标量>1μg/L时,间接竞争ELISA法与ICP-AES法检测Cr3+的符合率达96.95%。结论:获得效价高、特异性强的重金属Cr3+mAb,初步建立了检测Cr3+的间接竞争ELISA法,该方法检测的灵敏度可达到国家地下Ⅰ类水的检测标准(0.005 mg/L)。 AIM:To produce the monoclonal antibodies(mAb) against Heavy Metal Chromium,and develop a competitive inhibition enzyme-linked immunosorbent assay(ciELISA) for the detection of Chromium.METHODS: Chromium ions was chelated with bifunctional chelating agent Isothio-cyanobenzyl-EDTA firstly and then conjugated with bovin serum alburmin(BSA) and ovalbmin(OVA) respectively to complete antigens.Four female BALB/c mice were immunized with Cr-iEDTA-BSA,the Hybridoma lines secreting monoclonal antibodies against Chromium ions were established by the hybridoma technology.The titer and the specificity of the antibodies were characterized in the way of indirect enzym-elinked immunosorbent assay(iELISA) and ciELISA.RESULTS: After immunization and cell fusion,three hybridomaes which can stably secrete mAbs against chromium were obtained.The antibody titer was up to 1×105,only had 9.62% cross-reactivity to Fe3+ and little to other ions.Linear detection of ciELISA for Chromium covered a range from 0.783 μg/L-50 μg/L with the limit at the level of 1 μg/L.An excellent correlation of results obtained by ciELISA and ICP-AES when the concentration more than 1 μg/L.CONCLUSION: The monoclonal antibody against Chromium with high sensitivity and specificity has been generated and a competitive inhibition enzyme-linked immunosorbent assay for the detection of Chromium ions has been established successfully,which was met the the national standard of water quality nonitoring.
出处 《细胞与分子免疫学杂志》 CAS CSCD 北大核心 2011年第4期422-424,共3页 Chinese Journal of Cellular and Molecular Immunology
基金 国家"863"高技术发展计划目标导向项目(2008AA10Z427)
关键词 重金属 CR3+ 细胞融合 单克隆抗体 ELISA heavy metal chromium cell fusion mAb ELISA
  • 相关文献

参考文献10

  • 1Diane AB,Jones RM,Robert CB,et al.Antibody-based sensors for heavy metal ions[J].Biosens Bioelectron,2001,16(9-12):799-809. 被引量:1
  • 2Bontidean I,Lloyd JR,Hobman JL,et al.Bacterial metal-resistance proteins and their use in biosensors for the detection of bio-available heavy metals[J].J Inorganic Biochem,2000,79(124):225-229. 被引量:1
  • 3Reardan DT,Meares CF,Goodwin DA,et al.Antibodies against metal chelates[J].Nature,1985,316(6025):265-268. 被引量:1
  • 4Zhu XX,Xu LN,Lou Y,et al.Preparation of specific mAbs against heavy metals:mAbs that recognize chelated cadmium ions[J].Agric Food Chem,2007,55(19):7648-7653. 被引量:1
  • 5Zhu XX,Hu BS,Lou Y,et al.Characterization of monoclonal antibodies for lead chelate complexes:applications in antibody-based assays[J].Agric Food Chem,2007,55(13):4993-4998. 被引量:1
  • 6Xiang JJ,Zhai YF,Tang Y,et al.A competitive indirect enzyme-linked immunoassay for lead ion measurement using mAbs against the lead-DTPA complex[J].Environ Pollut,2010,158(5):1376-1380. 被引量:1
  • 7Darwish IA,Blake DA.One-step competitive immuncossay for cadmium ions:development and validation for enviromental water samples[J].Anal Chem,2001,73(8):1889-1895. 被引量:1
  • 8Sasaki k,Oguma S,Namiki Y,et al.Monoclonal antibody to trivalent chromium chelate complex and its application to measurement of the total chromium concentration[J].Anal Chem,2009,81(10):4005-4009. 被引量:1
  • 9唐勇,向军俭,罗辉武,邓宁,王宏.重金属镉离子单克隆抗体的制备[J].食品科学,2005,26(9):350-353. 被引量:18
  • 10王建华,唐勇,向军俭,王宏,杨红宇,凌钦婕.镉离子多克隆抗体ELISA竞争法的初步建立[J].中国生物制品学杂志,2008,21(1):56-59. 被引量:16

二级参考文献21

  • 1唐勇,向军俭,罗辉武,邓宁,王宏.重金属镉离子单克隆抗体的制备[J].食品科学,2005,26(9):350-353. 被引量:18
  • 2杜瑜,尚琪.环境镉污染人群健康影响研究回顾[J].卫生研究,2006,35(2):241-243. 被引量:22
  • 3张朝生,章申,何建邦.长江水系沉积物重金属含量空间分布特征研究——地统计学方法[J].地理学报,1997,52(2):184-192. 被引量:183
  • 4徐志凯.实用单克隆抗体技术[M].西安:陕西科学技术出版社,1992.177-190. 被引量:86
  • 5Bontidean I, Lloyd J R, Hobman J L, et al. Bacterial metalresistance proteins and their use in biosensors for the detection of bioavailable heavy metals [J]. Journal of Inorganic Biochemistry, 2000, 79(1-4): 225-229. 被引量:1
  • 6Corbisier P, Van Der Lelie D, Borremans B, et al. Whole cell-and protein-based biosensors for the detection of bioavailable heavy metals in environmental samples [J]. Analytica Chimica Acta, 1999, 387(3): 235-244. 被引量:1
  • 7Wah Chu K, Chow, King L. Synergistic toxicity of multiple heavy metals is revealed by a biological assay using a nematode and its Wansgenic derivative[J]. Aquatic Toxicology, 2002, 61(1-2): 53 - 64. 被引量:1
  • 8Reardan D T, Meares C F, Goodwin D A, et al. Antibodies against metal chelates [J]. Nature, 1985, 316 (6025): 265-268. 被引量:1
  • 9Diane A B, Jones R M, Robert C B, et al. Antibody-based sensors for heavy metal ions [J]. Biosensors and Bioelectronics,2001, 16:799-809. 被引量:1
  • 10Diane AB, Jones RM, Robert CB, et al. Antibody-based sensors for heavy metal ions. Biosensors & Bioelectronics,2001,16:799-809. 被引量:1

共引文献28

同被引文献140

引证文献6

二级引证文献45

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部