期刊文献+

镉离子多克隆抗体ELISA竞争法的初步建立 被引量:16

Development of Competitive ELISA for Cadmium Ion with Polyclonal Antibody
下载PDF
导出
摘要 目的制备抗镉离子螯合物的多克隆抗体,初步建立检测镉离子的ELISA竞争法。方法用双功能螯合剂iEDTA螯合Cd2+后,再与匙血蓝蛋白(KLH)偶联,合成完全抗原(Cd-iEDTA-KLH),免疫BALB/c小鼠,获得多克隆抗体。ELISA法检测其抗血清效价、特异性和灵敏度。结果多克隆抗体效价均大于1∶80000;特异性检测结果显示均产生了抗Cd-iEDTA抗体,与OVA、BSA无交叉反应。抗体除与Hg2+有较强的交叉反应外,同等抑制情况下,Mg2+、Ca2+、Fe3+、Cu2+、Ni2+、Zn2+与Cd2+浓度相差约1000倍,交叉反应率很低;ELISA竞争法对镉离子的检测限约为50ng/ml。结论初步建立了镉离子的ELISA竞争法,检测限达到无公害的国家卫生限量标准(100ng/g)。 Objective To prepare the polyclonal antibody against cadmium ion chelate and develop a competitive ELISA for cadmium.Methods Chelate cadmium ion with bifunctional chelating agent isothiocyanobenzyl-EDTA (iEDTA) and couple to keyhole limpet hemocyanin (KLH). Polyclonal antibody was prepared by immunizing BALB/c mice with the synthetic complete antigen Cd-iEDTA-KLH and analyzed for titer, sepcificity and sensitivity by ELISA. Results The prepared polyclonal antibody reached a titer of more than 1 : 80 000 and showed no cross reaction with OVA, BSA or many other heavy metal ions. However, it showed strong cross reaction with mercury ion. The sensitivity of the prepared antibody for cadmium ion was 1 000 times higher than those for other heavy metal ions including nmgnesium, calcium, iron, copper, nickel and zinc ions. The detection limit of cadmium ion by competitive ELISA with the prepared polyclonal antibody was 50 ng/ml. Conclusion A competitive ELISA for cadmium ion with polyclonal antibody was preliminarily developed, and its detetion limit met the requirement for safety of non-environmental pollution aquatic products.
出处 《中国生物制品学杂志》 CAS CSCD 2008年第1期56-59,共4页 Chinese Journal of Biologicals
基金 广东省科技计划项目基金资助(粤财企[2003]209 2003C20411)
关键词 镉离子 重金属 竞争ELISA 多克隆抗体 Cadmium ion Heavy metal Competitive ELISA Polyclonal antibody
  • 相关文献

参考文献12

  • 1Diane AB, Jones RM, Robert CB, et al. Antibody-based sensors for heavy metal ions. Biosensors & Bioelectronics,2001,16:799-809. 被引量:1
  • 2Bontidean I, Lloyd JR, Hobman JL,et al. Bacterial metal-resistance proteins and their use in biosensors for the detection of bioavailable heavy metals.J Inorganic Biochem,2000,79(1-4) :225-229. 被引量:1
  • 3Johnson DK, Combs SM, Parsen JD, et al. Lead analysis by antichelate fluorescence polarization immunoassay. Environ Sci Teehnol,2002,36:1042-1047. 被引量:1
  • 4Darwish IA, Blake DA. One-step competitive iwantmoassay for casmium ions: development and validation for environmental water samples. Anal Chem,2001,73:1889-1895. 被引量:1
  • 5Ibrahim AD, Blake DA. Development and validation of a one-step immunoassay determination of cadmium in human serum. Aria Chem,2002,74(1):52-58. 被引量:1
  • 6唐勇,向军俭,罗辉武,邓宁,王宏.重金属镉离子单克隆抗体的制备[J].食品科学,2005,26(9):350-353. 被引量:18
  • 7食品中镉限量卫生标准GB 15201-9.中华人民共和国国家标准,1994. 被引量:1
  • 8李继强,陈锡永,唐意佳,赵磷石,谢广宁,邓俊兴,丘义征.环境镉污染及其对人群健康影响的研究状况分析[J].中国公共卫生,2001,17(3):196-198. 被引量:24
  • 9杜瑜,尚琪.环境镉污染人群健康影响研究回顾[J].卫生研究,2006,35(2):241-243. 被引量:22
  • 10Blake DA, Chakrabarti P, hosraviani M. Metal binding properties of a monoclonal antibody directed toward metal-chelate Complexes. J Biol Chemi, 1996,271 ( 44 ) : 27677-27685. 被引量:1

二级参考文献33

  • 1尚琪,蔡诗文.污染区人群镉摄入量与肾损害的关系[J].环境与健康杂志,1993,10(5):193-196. 被引量:11
  • 2曹玉广,彭良斌,刘爱平,陈建伟,程志,包克光.环境镉污染与人体镉负荷关系的研究[J].环境与健康杂志,1995,12(6):244-246. 被引量:8
  • 3张朝生,章申,何建邦.长江水系沉积物重金属含量空间分布特征研究——地统计学方法[J].地理学报,1997,52(2):184-192. 被引量:183
  • 4徐志凯.实用单克隆抗体技术[M].西安:陕西科学技术出版社,1992.177-190. 被引量:86
  • 5Bontidean I, Lloyd J R, Hobman J L, et al. Bacterial metalresistance proteins and their use in biosensors for the detection of bioavailable heavy metals [J]. Journal of Inorganic Biochemistry, 2000, 79(1-4): 225-229. 被引量:1
  • 6Corbisier P, Van Der Lelie D, Borremans B, et al. Whole cell-and protein-based biosensors for the detection of bioavailable heavy metals in environmental samples [J]. Analytica Chimica Acta, 1999, 387(3): 235-244. 被引量:1
  • 7Wah Chu K, Chow, King L. Synergistic toxicity of multiple heavy metals is revealed by a biological assay using a nematode and its Wansgenic derivative[J]. Aquatic Toxicology, 2002, 61(1-2): 53 - 64. 被引量:1
  • 8Reardan D T, Meares C F, Goodwin D A, et al. Antibodies against metal chelates [J]. Nature, 1985, 316 (6025): 265-268. 被引量:1
  • 9Diane A B, Jones R M, Robert C B, et al. Antibody-based sensors for heavy metal ions [J]. Biosensors and Bioelectronics,2001, 16:799-809. 被引量:1
  • 10WHO,Cadmium.Evaluation of certain additives and contaminants Geneva:WHO,1989 被引量:1

共引文献58

同被引文献199

引证文献16

二级引证文献86

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题