摘要
本文提出了一种符合IEC62689标准的配电线路故障路径指示用一二次融合传感器技术方案。分析结论表明引入IEC62689标准能够适应我国国情,并能够起到技术引领作用。
In this article,a technical scheme of primary/secondary integration sensor was presented,which is up to IEC 62689 standard and used for fault passage indication in distribution network.The analysis results show that the introduction of IEC 62689 standard can adapt to China's national conditions and play a leading role in technology.
作者
刘鹍
张显忠
李福超
罗睿希
叶子阳
艾兵
LIU Kun;ZHANG Xian-zhong;LI Fu-chao;LUO Rui-xi;YE Zi-yang;AI Bing(Sichuan Electric Power Corporation Metering Center,Chengdu 610045,China;Shenyang Transformer Research Institute,Shenyang 110122,China)
出处
《变压器》
北大核心
2020年第3期61-64,共4页
Transformer
基金
国网四川省电力公司科技项目(IEC 62689标准转化适用性验证研究)。
关键词
配电网
故障探测
一二次融合传感器
IEC
62689
Distribution network
Fault detection
Primary/secondary integration sensor
IEC 62689