期刊文献+

BiTAC离子膜电解槽膜极距改造的降耗效果和经济分析 被引量:12

Energy-saving effects of transforming BiTAC ion-exchange membrane electrolyzers into membrane-thickness electrode-distance ones and economic analysis
下载PDF
导出
摘要 叙述了将第1期BiTAC常极距离子膜电解槽改造为i-BiTAC膜极距电解槽的运行情况。改造前后参数对比分析显示降耗效果明显,经济效益显著,并为第2期BiTAC常极距离子膜电解槽升级为i-BiTAC膜极距电解槽奠定了基础。 The running situation of i-BiTAC ion-exchange membrane electrolyzers with membrane- thickness electrode-distance which were transformed from the first stage of BiTAC ones with ordinary electrode distance was described. Running parameters before and after transformation were compared, showing that the transformation created remarkable energy-saving effects and economic benefit. Foundation was laid for upgrading the second stage of BiTAC electrolyzers with ordinary electrode distance to ones with membrane-thickness electrode-distance.
出处 《氯碱工业》 CAS 2015年第2期5-7,24,共4页 Chlor-Alkali Industry
关键词 离子膜电解槽 膜极距电解槽 改造 弹性网 降耗 经济效益 ion-exchange membrane electrolyzer membrane-thickness electrode-distance electrolyzer transformation elastic net consumption reduction economic benefit