针对剩余氨水蒸氨工艺中经常出现碱计量泵流量不稳、剩余氨水反压入碱槽、蒸氨出水不达标等问题,采用舍弃计量泵、在剩余氨水泵前加碱、同时探索蒸氨塔气相组分直接入饱和器,通过以上措施,在确保蒸氨出水氨氮指标合格的同时,也达到了节约能源的目的。
For resolving such frequently occured problems as unstable flow of lye metering pump,residual ammonia water being reversely pressuredinto lye tank,unqualified wastewater of ammoniac distilling system,the following measures are adopted,such as abandonment of lye meteringpump,injecting lye in front of residual ammonia water pump,experimenting to let gaseous component of distilling ammonia tower directlyinto saturator,so we can ensure both qualification of wastewater of ammoniac distilling system and energy conservation.
出处
《广东化工》
CAS
2011年第12期121-122,115,共3页
Guangdong Chemical Industry
关键词
剩余氨水
蒸氨系统
工艺优化
residual ammonia water
ammoniac distilling system