期刊文献+

波前像差仪测量近视患者低阶像差的临床研究 被引量:8

Clinical research of lower order aberrations in myopia patients measured with wavefront aberration analyzer
下载PDF
导出
摘要 目的:通过波前像差仪与自动验光仪、综合验光仪3种方法测量近视患者屈光状态结果的对比观察,探讨波前像差仪对低阶像差测量的准确性。方法:随机选取2005-06/2005-09来我院进行LASIK术前检查的近视患者67例100眼,分别应用波前像差仪、自动验光仪、综合验光仪对其球镜度数、柱镜度数、散光轴向测量后进行统计分析、比较。结果:波前像差仪、自动验光仪、综合验光仪3种方法测得的球镜度数分别为-6.18±2.77,-5.80±2.80,-5.88±2.72D;柱镜度数分别为-0.73±0.57,-0.75±0.59,-0.72±0.56D;散光轴向中位数分别为66.00°,45.50°,27.50°,四分位数间距分别为162.75° ̄11.25°,160.00°~4.25°,161.00°~5.00°;等效球镜度分别为-6.55±2.90,-6.17±2.91,-6.24±2.81D;统计学上均无显著性差异。结论:波前像差仪在准确测量眼高阶像差的同时,能够准确地测量近视患者的低阶像差。 AIM: To compare the results of refractive errors in myopia patients measured with wavefront aberration analyzer, autorefraction and phoropter, further to evaluate the accuracy of wavefront aberration analyzer in measuring refractive errors. METHODS: Wavefront aberration analyzer, autorefraction and phoropter were used respectively to measure the refractive errors in 100 eyes of 67 patients with ametropia which were randomly selected. The degrees of myopia, astigmatism and the axis values of astigmatism were recorded and analyzed by statistic software (SPSS). RESULTS: The degrees of myopia measured with wavefront aberration analyzer, autorefraction and phoropter were -6.18± 2.77,-5.80±2.80,-5.88±2.72D respectively. The degrees of astigmatism were -0.73±0.57,-0.75±0.59,-0.72±0.56D respectively. The medians of the axis values of astigmatism were 66.000,45.50°, 27.50° respectively, the quartile intervals were 162.75°-11.25°, 160.00°-4.25°, 161.00°-5.00° respectively. The spherical equivalents were -6.55±2.90, -6.17±2.91,-6.24±2.81D respectively. There were no statistically significant differences in the results among the three different instruments. CONCLUSION: The results of both higher and lower order aberration in myopia patients measured with wavefront aberration analyzer are accurate and reliable.
出处 《国际眼科杂志》 CAS 2006年第3期639-641,共3页 International Eye Science
关键词 低阶像差 屈光不正 波前像差 lower order aberration refractive error wave-front aberration
  • 相关文献

参考文献9

二级参考文献19

  • 1徐世平.电脑验光仪和角膜曲率计在小儿眼科的应用[J].中国斜视与小儿眼科杂志,1996,4(4):184-185. 被引量:6
  • 2赵炜,徐渊,王雨生,惠延年.个体化切削和超常视力[J].国际眼科杂志,2004,4(5):895-899. 被引量:4
  • 3任华明 封治国 等.自动电脑验光仪在小儿眼科的应用[J].中华眼科杂志,1992,28:79-79. 被引量:19
  • 4Applegate RA, Howland HC, Sharp RP, Cottingham AJ, Yee RW. Corneal aberrations and visual performance after radial keratotomy. J Refract Surg,1998;14:397-405 被引量:1
  • 5Oshika T, Miyata K, Tokunaga T, Samejima T, Amano S, Tanaka S, Hirohara Y, Mihashi T, Maeda N, Fujikado T. Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis. Ophthalmology, 2002; 109:1154-1158 被引量:1
  • 6Mattioli,Tripoli NK. Corneal geometry reconstruction with the Keratron videokeratographer. Optom Vis Sci,1997;74:881-894. 被引量:1
  • 7Oshika T, Klyce SD, Applegate RA, Howland HC, Danasoury MA. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. Am J Ophthalmol, 1999; 127:1-7 被引量:1
  • 8Cohen KL, Tripoli NK, Holmgren DE, Nishida T. Assessment of the power and height of radial aspheres reported by a computer-assisted keratoscope.Am J Ophthalmol, 1995; 119:723 -732 被引量:1
  • 9Mrochen M, Kaemmerer M, Mierdel P, Seiler T. Increased higher-order optical aberrations after laser refractive surgery: A problem of subclinical decentration. J Cataract Refractive S urg; 2001 ;27:362-369 被引量:1
  • 10Mattioli R. Corneal topography and wavefront analysis. In: Caimi, Brancato R. eds. The aberrometers. Novara: Fabiano/Slack,2003:113-132 被引量:1

共引文献53

同被引文献77

引证文献8

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部