炫速双源CT心周脂肪及心外膜脂肪体积测定与冠状动脉粥样硬化的相关性研究 被引量:3

下载PDF
导出
摘要 目的:探讨炫速双源CT心周脂肪及心外膜脂肪体积测定与冠状动脉粥样硬化(CAS)的相关性。方法:回顾以往4年我院放射科接收的174例CAS患者资料进行分析,根据检测结果分为两组,阴性组(60例)为测定阴性者,阳性组(114例)为测定阳性者,观察两组心周及心外膜CAS阳性、阴性脂肪体积及冠脉狭窄程度变化。结果:阴性组患者心周及心外膜脂肪体积指数显著低于阳性组(P<0.05);心周及心外膜脂肪体积各冠心病狭窄程度评估各程度指数同期对比具有显著差异(P<0.05)。结论:CAS患者心周脂肪体积变化与心外膜变化可影响疾病的发展,指数越高CAS狭窄程度越严重,运用价值显著。
出处 《影像研究与医学应用》 2018年第2期168-169,共2页 Journal of Imaging Research and Medical Applications
  • 相关文献

参考文献6

二级参考文献49

  • 1陈月芹,孙占国,王林省,史志涛,贾存玮,张谷青,张新东,王彦辉,李慧,王玉红.前瞻性心电门控技术在双源CT冠状动脉成像中的应用价值[J].医学影像学杂志,2012,22(2):178-181. 被引量:8
  • 2张宗军,卢光明.双源CT及其临床应用[J].医学研究生学报,2007,20(4):416-418. 被引量:106
  • 3王纯正,徐智章.超声诊断学[M].北京:人民卫生出版社,2008:318. 被引量:8
  • 4Westwood M,Al M,Burgers L,et al. A systematic review and economic evaluation of new-generation computed tomography scanners for imaging in coronary artery disease and congenital heart disease: Somatom Definition Flash,Aquilion ONE,Brilliance iCT and Discovery CT 750 HD[J]. Health Technology Assessment, 2013,17 (9) : 1-243. 被引量:1
  • 5Paul J, Banckwitz R, Krauss B ,et al. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length- product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT[J]. Eur J Radiol, 2012,81 (4) : 507 -512. 被引量:1
  • 6Paul J, Krauss B, Banckwitz R ,et ol. Relationships of clinical proto-cols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner:Study with an anthropomorphic and water phantom[J]. Eur J Radiol, 2012,81 (5) : 699-703. 被引量:1
  • 7Lundin M, Liden M, Magnuson A, et al. Virtual non-contrast dual- energy CT compared to single-energy CT of the urinary tract : A pros- pective study[J]. Acta Radiol, 2012,53 (6) : 689-694. 被引量:1
  • 8Jepperson M A,Thiel D D, Cemigliaro J G,et al. Determination of ur- eter stent appearance on dual-energy computed tomography scan[J]. Urology, 2012,80 (5) : 986-989. 被引量:1
  • 9Winklehner A,Karlo C,Puippe G,et al. Raw data-based iterative reconstruction in body CTA :Evaluation of radiation dose saving potential[J]. Eur Radiol, 2011,21 (12) : 2 521-2 526. 被引量:1
  • 10Takata T, Ichikawa K, Hayashi H,et al. Image quality evaluation of new image reconstruction methods applying the iterative reconstruc- tion[J]. Nihon Hoshasen Gij utsu Gakkai Zasshi, 2012,68 (4) : 404-412. 被引量:1