期刊文献+

风机过滤单元箱体结构与面出风均匀性测点分布的优化 被引量:3

Optimization of structure of fan filter unit and test point distribution of air velocity uniformity
下载PDF
导出
摘要 采用数值模拟方法研究常规商用1175 mm×1175 mm(4×4模数)风机过滤单元(fan filter unit,FFU)的马达底板形状、静压箱厚度等结构特性与面出风均匀性的关系,并探究了不同测点分布对测试结果的影响。结果表明:对于4×4模数的FFU,可通过减小马达底板面积和增大静压箱厚度来提高出风均匀性,但存在临界静压箱厚度;在进行出风均匀性测试时,测点分布对测试结果有较大影响,其中6×6中心分布的方法最为适宜。 The relationship between the structural characteristics(i.e.,motor baseplate shape and plenum chamber thickness)of the common commercial 1175 mm×1175 mm(4×4 module)fan filter unit(FFU)and the air velocity uniformity was studied using numerical simulation methods.The influence of test point distribution on the test results was explored.The results show that for the 4×4 module FFU,a higher uniformity can be achieved by reducing the area of motor baseplate and increasing the thickness of plenum chamber,but there is a critical thickness of plenum chamber.When testing the air velocity uniformity,the distribution of test point has a great influence on the results,and the method of 6×6 central distribution is the most suitable.
作者 徐佳佳 贾洪伟 钟珂 亢燕铭 XU Jiajia;JIA Hongwei;ZHONG Ke;KANG Yanming(College of Environmental Science and Engineering,Donghua University,Shanghai 201620,China)
出处 《东华大学学报(自然科学版)》 CAS 北大核心 2021年第2期84-89,共6页 Journal of Donghua University(Natural Science)
基金 上海市扬帆计划资助项目(18YF1400700) 国家自然科学基金资助项目(41590875,41590871) 中国博士后基金资助项目(2018M641891)。
关键词 风机过滤单元 出风均匀性 测点分布 马达底板形状 静压箱厚度 fan filter unit air velocity uniformity test point distribution motor baseplate shape plenum chamber thickness
  • 相关文献

参考文献6

二级参考文献22

  • 1洪玉忠.探讨FFU净化单元在生物制药洁净室的应用[J].医药工程设计,2008,29(6):44-47. 被引量:6
  • 2[1]Xu Zhonglin. Cleanroom Technology Theory[M]. Shanghai: Press of Tongji University, 1998. 被引量:1
  • 3[2]Dou Guoren. Turbulence Machanics[M]. Beijing: People Education Press, 1981. 被引量:1
  • 4[3]Zhao Rongyi, Fan Cunyang, Xue Dianhua et al. Air Conditioning[M]. Beijing: Press of China Construction Industry, 1994. 被引量:1
  • 5[4]Yang Yanan. Study on the Structure and the Using Effect of Laminar Hood Rectifier[D]. Tianjin: Tianjin University, 1996. 被引量:1
  • 6[5]Federal Standard 209E, Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones[S]. 被引量:1
  • 7[6]IEST-RP-CC006.2-1997, Testing Clean Rooms[S]. 被引量:1
  • 8[7]Liu Bing. Time Sequence Analysis Method of Room Airflow Measurement[D]. Tianjin: Tianjin University, 1995. 被引量:1
  • 9许钟麟.空气洁净技术原理[M].北京:科学出版社,2003. 被引量:41
  • 10Xu Tengfang, Jeng Mingshan. Laboratory evaluation of fan-filter units' aerodynamic and energy performance [ J]. Journal of the lEST, 2004, 47(1) : 116 -120. 被引量:1