摘要
目的分析丙氨酸转氨酶(ALT)检测质量控制对无偿献血者招募的影响。方法采用校准物和质控品定期对ALT检测设备进行校准和质量控制。比较分析实施定期校准和质量控制前后无偿献血者ALT淘汰率。结果ALT的淘汰率由1.88%下降到0.48%,ALT淘汰数占总淘汰数的比例由48.15%下降到20.36%。结论定期对ALT检测设备进行校准和质量控制,能有效减少ALT淘汰引起的血液浪费,稳定献血者队伍,提高献血者献血积极性。
Objective To analyzed the effeet of quality control on ALT detection on the recruitment of free blood donors . Methods Calibrations and quality control products are regularly calibrated and quality controlled for ALT testing equipment. The ALT elimination rate of non remunerated blood donors before and after regular calibration and quality control was compared and analyzed. Results The elimination rate of ALT dropped from 1.88% to 0.48%, and the proportion of the ALT elimination number to the total elimination number decreased from 48.15% to 20.36%.Conclusion Regular calibration and quality control of ALT testing equipment can effectively reduce the waste of blood caused by ALT elimination before ALT screening, stabilize the team of blood donors, and improve the enthusiasm of blood donors.
作者
许虹
张剑英
张柳明
陕柏峰
Xu Hong;Zhang Jianying;Zhang Liuming(The Re d Cross Blood Center of Taiyucal City,Taiyuan,Shanxi 030001)
出处
《基层医学论坛》
2018年第31期4376-4378,共3页
The Medical Forum
关键词
丙氨酸转氨酶检测
质量控制
无偿献血
招募
影响
ALT detection
Quality control
Unpaid blood donation
Recruitment Influence