摘要
针对Φ3.2×3.1m格子型球磨矿分级系统中螺旋分级机故障率高,磨机电耗高,分级作业消耗大量清水资源等缺点,提出了Φ3.2×3.1m格子型球磨矿分级系统改进方案和措施,满足节能环保的需要。实践证明,改造后Φ3.2×3.1m格子型球磨矿分级系统运行稳定,故障率低,维修工作量小,磨矿分级指标提高明显,节能环保效果明显,取得良好效果。
For the high failurerate of Ф3.2×3.1m grinding and classificationsystem and Consumption ofplenty of waterand powerresources, the article proposed the improvementprograms and measures of Ф3.2×3.1m grinding and classificationsystem, which can meetthe needs ofenergy saving. Practice proves that the grinding and classificationsystem is stable and lowfailure rate after transformation. Energy savingeffect is obvious.
作者
李春华
苏辉财
LI Chun-hua SU Hui-cai(Dexing Copper Mine, Jiangxi Copper Corporation, Dexing 334224, Jiangxi, Chin)
出处
《铜业工程》
CAS
2017年第5期37-39,共3页
Copper Engineering
关键词
格子型球
磨矿分级系统
高故障率
旋流器分级
自动控制
运转率高
节能环保
lattice-typeball mill
grinding and classificationsystem
high failurerate
cycloneclassification
automatic control
high operating rate
energy saving