期刊文献+

基于深度学习的人体低氧状态识别 被引量:6

Recognition of human hypoxic state based on deep learning
原文传递
导出
摘要 通过低氧实验提出一种快速识别人体低氧状态的方法.通过搭建深层神经网络训练实验数据识别氧气体积分数(16%~21%)与人体可耐受极端低氧气体积分数(15. 5%~16%)条件下光电容积脉搏波(photoplethysmography,PPG)信号,获得人体生理状态的模式识别网络.经测试该网络的识别正确率可达92. 8%.利用混淆矩阵及接受者操作性能(receiver operating characteristic,ROC)曲线分析,混淆矩阵的训练集、验证集、测试集、全集识别正确率分别达到97. 9%、94. 8%、92. 8%和96. 3%,AUC (area under curve)值接近1,认为该网络分类性能优良,并且可在4 s内完成整个识别过程. Due to the development of industrialization,low-oxygen environment has become common in the confined spaces of construction industries,chemical industries,military,urban underground spaces,and poorly ventilated crowed areas and caused a large number of hypoxic injuries.The traditional method of preventing hypoxic injuries is to monitor the oxygen concentration in the environment without considering the difference in oxygen tolerance limits when the human body is in different physiological states.Photoplethysmography(PPG)can comprehensively reflect physiological information,including heart rate,blood pressure,blood oxygen saturation,cardiovascular blood flow parameters,and respiratory rate.When the human body enters a hypoxic environment,the physiological parameters change rapidly,resulting in a change in the PPG signal.By measuring the PPG signal of the human body,the physiological state is considered to determine whether the human body reaches the oxygen tolerance limit.This study proposed a method for quickly identifying the hypoxic state of the human body using hypoxia experiment.According to the latest research on aviation medicine,mountain medicine and naval submarine medicine,15.5%oxygen volume fraction can guarantee the basic life safety of personnel.Through the training experimental data of a constructed deep neural network,the PPG signal of a human in normal oxygen volume fraction(16%-21%)and extremely low-oxygen volume fraction(15.5%-16%)was determined to obtain the pattern recognition network of human physiological state.After testing,the recognition accuracy of the network could reach 92.8%.Using the confusion matrix and receiver operating characteristic curve analysis,the accuracy rate of training set,verification set,test set,and ensemble recognition of the confusion matrix reached 97.9%,94.8%,92.8%,and 96.3%,respectively.The area under the curve value is close to 1,the network classification performance is excellent,and the entire identification process could be completed within 4 s.
作者 于露 金龙哲 王梦飞 徐明伟 YU Lu;JIN Long-zhe;WANG Meng-fei;XU Ming-wei(School of Civil and Resource Engineering,University of Science and Technology Beijing,Beijing 100083,China)
出处 《工程科学学报》 EI CSCD 北大核心 2019年第6期817-823,共7页 Chinese Journal of Engineering
基金 国家“十三五”重点科技支撑资助项目(2016YFC0801700)
关键词 有限空间 低氧伤害 光电容积脉搏波 深度学习 状态识别 confined space hypoxic injury photoplethysmography deep learning state recognition
  • 相关文献

参考文献4

二级参考文献27

  • 1张敏,李涛,陈曙旸,杜燮祎,王焕强,张爽,秦戬,王鸿飞.我国硫化氢中毒的特点与控制对策[J].工业卫生与职业病,2005,31(1):12-14. 被引量:56
  • 2黄鸿基.有限空间作业安全卫生[J].铁道劳动安全卫生与环保,1995,22(3):230-231. 被引量:2
  • 3霍戌文,李伟,李进,陈科.光电探测微信号放大器设计[J].浙江理工大学学报(自然科学版),2005,22(3):259-262. 被引量:36
  • 4严新忠,杨静,郭略.人体血氧饱和度监测方法的研究[J].医疗装备,2005,18(12):1-4. 被引量:41
  • 5张敏,李涛,王焕强,王鸿飞,陈曙旸,杜燮祎,秦戬,张爽,纪丽颖.1989至2003年全国窒息性气体重大急性职业中毒的特征[J].中华劳动卫生职业病杂志,2006,24(12):712-715. 被引量:36
  • 6Nijboer J A, Dorlas J C, Mahieu H F. Photoelectric plethysmography-some fundamental aspects of the reflection and transmis sion methods[J]. Clinical Physics and Physiological Measurement, 1981, 2: 205--215. 被引量:1
  • 7Bernardi L. , Radaelli A. , Solda' P L. Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves[J].Clinic Science, 1996, 90:345-355. 被引量:1
  • 8Anders Johansson, Per Ake Oberg, Gunnar Sedin. Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique[J].Journal of Clinical Moni toring and Computing, 1999,15 : 461-467. 被引量:1
  • 9Nilsson L, Johansson A, Kalman S. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique[J]. Journal of Clinical Monitoring and Computing, 2000,16: 309-315. 被引量:1