期刊文献+

片状钽粉径厚比测试方法研究 被引量:1

Research on Test Method for radius-to-thickness ratio of Flake Tantalum Powder
原文传递
导出
摘要 本文通过构造片状钽粉模型,建立了片状型粉末的数学模型和测试模型,并确定了片状钽粉长度、厚度及径厚比测试方法。测量前,片状钽粉先经分散处理,然后金相镶嵌并切片磨削。利用光学显微镜从水平截面测量长度的平均值,从垂直截面测量厚度的平均值,计算得出片状钽粉的径厚比,并对所得测试数据进行数理统计并进行修正,得出片状钽粉的最终径厚比。研究表明:该测试方法可以方便测试片状钽粉的平均长度、厚度及径厚比。当测量颗粒数达到200个以上时,测试数据趋于稳定,具有良好的重现性和较小的误差。 The mathematical model and test model of flake tantalum powder were established by constructing the model of the flake tantalum powder, and the test methods for the length, thickness and radius-to-thickness ratio of the flake tantalum powder were determined. The flake tantalum powder was firstly dispersed before measurement, then metallographic mosaic and slice grinding were carried out. The average value of the length on horizontal section and the average value of the thickness on vertical section were measured by optical microscope, and the radius-to-thickness ratio of the flake tantalum powder was calculated. The test data was statistically analyzed and corrected, and the ultimate radius-to-thickness ratio of the flake tantalum powder was obtained. The results show that the test method is convenient to test the average length,thickness and radius-to-thickness ratio of the flake tantalum powder. When the number of particles measured is over 200,the test data tends to be stable with good reproducibility and smaller deviation.
出处 《硬质合金》 CAS 2015年第4期272-278,共7页 Cemented Carbides
关键词 片状钽粉 测量模型 数理修正 径厚比 flake tantalum powder measurement model mathematical correction radius-to-thickness ratio
  • 相关文献

参考文献13

二级参考文献45

共引文献57

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部