摘要
对3款同种型号不同公司生产的双极电压比较器进行了高、低剂量率及变温辐照的60 Coγ辐照实验。结果表明:偏置电流和电源电流为双极电压比较器辐射敏感参数,失调电压仅在工作偏置条件下为辐射敏感参数;由于工艺不同,不同公司的双极电压比较器存在辐射响应差异,而同一公司的双极电压比较器在不同偏置条件下的辐照损伤趋势亦不同;变温辐照加速评估方法不仅可鉴别上述不同公司的双极电压比较器在不同偏置条件下的剂量率效应,而且能很好地模拟和保守地评估其低剂量率下的辐照损伤。
With different irradiation methods , ionizing radiation responses of bipolar voltage comparators of three manufacturers were investigated .The results show that the input bias current and power current are the most sensitive parameters ,and the in‐put offset voltage is only sensitive to total dose in working state .Different bipolar volt‐age comparators from different companies have diverse radiation responses due to vari‐ous crafts .This method can perfectly simulate and conservatively evaluate low dose rate damage of those devices in various bias conditions .
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2014年第11期2170-2176,共7页
Atomic Energy Science and Technology
关键词
双极电压比较器
60Coγ辐照
低剂量率
变温辐照
bipolar voltage comparator 60 Co γ irradiation low dose rate temperature switching irradiation