摘要
采用试验的方法,在相同的外界环境温度和湿度条件下,模拟最常见的两种引起冷藏集装箱冷凝风机风量下降的因素。试验结果表明,风机性能下降及垛距过小会减少冷凝风机的冷凝风量,从而增加系统制冷时间和功耗;为了保证有效通风,垛距至少要达到1 m才能保证冷凝风机有效工作。
In the same external environment temperature and humidity conditions,the experimental tests were deployed to monitor two common factors that reduce condensing air flow rate.The experimental results showed that reduced condensing fan performance and too small container distance will decrease condensing air flow rate,and increase the cooling time and power consumption.In order to ensure effective work of condensing fan,the container distance should not be less than 1 meter.