期刊文献+

基于四维和三维CT的肝癌靶区与正常组织位移分析 被引量:5

原文传递
导出
摘要 经导管动脉化疗栓塞术结合术后放疗已成为无法手术切除的原发性肝癌的主要治疗方式之一,然而,肝脏位置受呼吸运动影响较大,会影响到肝癌靶区确定。已有文献报道了肝癌放疗计划中呼吸运动造成的肿瘤及邻近正常组织剂量学误差。相对于四维CT(four—dimensional CT,4DCT)临床常用的3DCT模拟定位靶区位置确定以及与邻近正常组织位置关系有待探讨。
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2012年第3期261-262,共2页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献4

  • 1Wu QJ,Thongphiew D, Wang Z,et al. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer. Med Phys,2008,35:1440-1451. 被引量:1
  • 2Vdee M,Mosdey JL,Eecles CL,et al. Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration. Int JRadiat Oneol Biol Phys,2011,80: 265 -272. 被引量:1
  • 3Case RB, Moseley DJ, Sonke JJ, et al. Interfraction and intrafraction changes in amplitude of breathing motion in stereotactic liver radiotherapy. Int J Radiat Oncol Biol Phys,2010, 77:918-925. 被引量:1
  • 4习勉,刘孟忠,李巧巧,蔡玲,张黎,胡永红.基于4DCT的腹部器官呼吸运动分析[J].癌症,2009,28(9):989-993. 被引量:24

二级参考文献21

  • 1习勉,刘孟忠,邓小武,刘慧,黄晓延,张黎,李巧巧,胡永红,蔡玲,崔念基.应用4D-CT技术确定肝癌内靶体积及相关剂量学研究[J].癌症,2007,26(1):1-8. 被引量:13
  • 2International Commission Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy. Supplement to report 50. Report 62 [R]. Washington, DC: ICRU, 1999. 被引量:1
  • 3Rietzel E, Chen GT, Choi NC, et al. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion [J]. Int J Radiat Oncol Biol Phys, 2005,61 (5):1535-1550. 被引量:1
  • 4Keall PJ, Joshi S, Vedam SS, et al. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking [ J ]. Med Phys, 2005,32 (4) : 942-951. 被引量:1
  • 5Underberg RW, Lagerwaard F J, Slotman B J, et al. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets [J]. lnt J Radiat Oncol Biol Phys, 2005,62 (2) : 554-560. 被引量:1
  • 6vander Geld YG, Senan S, van Somsen de Koste JR, et al. Evaluating mobility for radiotherapy planning of lung tumors: a comparison of virtual fluoroscopy and 4DCT [J]. Lung Cancer, 2006,53 ( 1 ) : 31-37. 被引量:1
  • 7Rietzel E, Pan T, Chen GT. Four-dimensional computed tomography: image formation and clinical protocol [J]. Med Phys, 2005,32(4) : 874-889. 被引量:1
  • 8Pan T, Lee TY, Rietzel E, et al. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J]. Med Phys, 2004,31 (2) : 333-340. 被引量:1
  • 9Baiter JM, Dawson LA, Kazanjian S, et al. Determination of ventilatory liver movement via radiographic evaluation of diaphragm position [J]. Int J Radiat Oncol Biol Phys, 2001, 51 ( 1 ) : 267-270. 被引量:1
  • 10Davies SC, Hill AL, Holmes RB, et al. Ultrasound quantitation of respiratory organ motion in the upper abdomen [J]. Br J Radiol, 1994,67(803): 1096-1102. 被引量:1

共引文献23