摘要 为补偿肝脏运动,分析呼吸引起的肝脏空间运动和形变,并尝试将其简化为刚性运动模型进行补偿.利用基于表面和基于互信息的3D-3D图像刚性配准方法分析4例肝脏空间运动的规律并进行补偿,比较使用手工分割肝脏轮廓和肝脏灰度信息进行配准的结果及其补偿效果,评估2种思路的可靠性,并进一步评价刚体运动模型简化的可行性.结果表明:刚性运动模型、简化的平移运动模型和矢状面2D运动模型在实际应用中具有可行性,此3种模型都可以补偿80%以上的呼吸影响;使用肝脏灰度信息比手工分割轮廓建模和补偿的结果更可靠.上述结论对在超声融合多模成像中快速建模和实时补偿呼吸对肝脏运动的影响有一定的参考价值. The respiration-induced liver motion and deformation was analyzed, and a rigid motion model was utilized to simplify the liver motion and compensate for it. 3D-3D image rigid registration was applied to obtain the motion parameters of four livers using surface and mutual information as the cost function re- spectively. Then the liver motion patterns were analyzed and the motion was compensated based on these parameters. Afterwards, the registration results and compensation performance, as well as their reliability were compared between manual segmented liver contour group and liver gray scale information group. Fur- thermore, the feasibility of the rigid model's further simplification was evaluated. The result shows that the rigid model and the further simplified translation motion model, even the 2D sagittal in-plane transla- tion motion model are feasible. Over 80o/4 of respiratory affection can be avoided using the simplified mo- tion models. The modeling and compensation of liver motion using liver gray scale information is more credible than those using manual segmented liver contour. The above conclusion is valuable for real-timely compensating for respiration-induced liver motion in ultrasound fusion multimodal imaging in engineering.
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2014年第9期1710-1720,共11页 Journal of Zhejiang University:Engineering Science
基金 国家自然科学基金资助项目(81271671 81271735)
关键词 呼吸 肝脏运动 刚性运动模型 补偿 respiration liver motion rigid motion model compensation
  • 相关文献

参考文献17

  • 1EWERTSEN C, SAFTOIU A, GRUIONU L G, et al. Real-time image fusion involving diagnostic ultrasound rJ. American Journal Roentgenology, 2013, 200 (3) .. 249 - 255. 被引量:1
  • 2Daniela Larisa Sandulescu,Daniela Dumitrescu,Ion Rogoveanu,Adrian Saftoiu.Hybrid ultrasound imaging techniques(fusion imaging)[J].World Journal of Gastroenterology,2011,17(1):49-52. 被引量:7
  • 3EWERTSEN C, HANSEN K L, HENRIKSEN B M, et al. Improving accuracy for image fusion in abdominal ultrasonography [J]. Diagnostics, 2012, 2(4): 34-41. 被引量:1
  • 4BRANDNER E D, WU A, CHEN Hung-cheng, et al. Abdominal organ motion measured using 4D CT [J]. International Journal of Radiation Oncology Biology Phys- ics, 2006, 65(2): 554-560. 被引量:1
  • 5WIESNER S. Respiration monitoring and tomographie reconstruction towards 4D cone beam CT [D]. Wash- ington, DC: Georgetown University, 2007. 被引量:1
  • 6习勉,刘孟忠,李巧巧,蔡玲,张黎,胡永红.基于4DCT的腹部器官呼吸运动分析[J].癌症,2009,28(9):989-993. 被引量:24
  • 7TANNER C, BOYE D, SAMEI G, et al. Review on 4Dmodels for organ motion compensation [J]. Critical Re- views in Biomedical Engineering, 2012, 40 (2) : 135 - 154. 被引量:1
  • 8CHRISTINA L W C, TUBLIN M E, CHAPMAN B E. Registration of MR and CT images of the liver: compari- son of voxel similarity and surface based registration al- gorithms [J]. Comput Methods Programs Biomed, 2005, 78(2) : 101 - 114. 被引量:1
  • 9ROHLFING T, MAURER J C R, O'DELL W G, et al. Modeling liver motion and deformation during the re- spiratory cycle using intensity-based free-form registra- tion of gated MR images[C] // Medical Imaging 2001. Bellingham, USA: International Society for Optics and Photonics : 2001 : 337 - 348. 被引量:1
  • 10LANGE T, WENCKEBACH T, LAMECHER H, et al. Registration of portal and hepatic venous phase of MR/CT data for computer-assisted liver surgery plan- ning [C] ff International Congress Series. Rio de Janei- ro: Elsevier, 2005, 1281: 768-772. 被引量:1

二级参考文献36

  • 1习勉,刘孟忠,邓小武,刘慧,黄晓延,张黎,李巧巧,胡永红,蔡玲,崔念基.应用4D-CT技术确定肝癌内靶体积及相关剂量学研究[J].癌症,2007,26(1):1-8. 被引量:13
  • 2International Commission Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy. Supplement to report 50. Report 62 [R]. Washington, DC: ICRU, 1999. 被引量:1
  • 3Rietzel E, Chen GT, Choi NC, et al. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion [J]. Int J Radiat Oncol Biol Phys, 2005,61 (5):1535-1550. 被引量:1
  • 4Keall PJ, Joshi S, Vedam SS, et al. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking [ J ]. Med Phys, 2005,32 (4) : 942-951. 被引量:1
  • 5Underberg RW, Lagerwaard F J, Slotman B J, et al. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets [J]. lnt J Radiat Oncol Biol Phys, 2005,62 (2) : 554-560. 被引量:1
  • 6vander Geld YG, Senan S, van Somsen de Koste JR, et al. Evaluating mobility for radiotherapy planning of lung tumors: a comparison of virtual fluoroscopy and 4DCT [J]. Lung Cancer, 2006,53 ( 1 ) : 31-37. 被引量:1
  • 7Rietzel E, Pan T, Chen GT. Four-dimensional computed tomography: image formation and clinical protocol [J]. Med Phys, 2005,32(4) : 874-889. 被引量:1
  • 8Pan T, Lee TY, Rietzel E, et al. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J]. Med Phys, 2004,31 (2) : 333-340. 被引量:1
  • 9Baiter JM, Dawson LA, Kazanjian S, et al. Determination of ventilatory liver movement via radiographic evaluation of diaphragm position [J]. Int J Radiat Oncol Biol Phys, 2001, 51 ( 1 ) : 267-270. 被引量:1
  • 10Davies SC, Hill AL, Holmes RB, et al. Ultrasound quantitation of respiratory organ motion in the upper abdomen [J]. Br J Radiol, 1994,67(803): 1096-1102. 被引量:1

共引文献29

同被引文献7

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部