期刊文献+

地铁消防安全性能化评估 被引量:8

The fire safety assessment in metro
下载PDF
导出
摘要 结合地铁内行人紧急疏散的交通特性,针对地铁火灾的危险性及其特点,利用性能化评估方法对地铁消防安全进行分析,再利用Legion软件模拟火灾情况下人员疏散,用安全疏散容量和人员疏散时间两个指标对地铁消防安全进行性能化评估。以某双层地铁站为例,设定火灾发生在列车上的场景,计算可知闸机容量最小,为地铁站的安全疏散容量。闸机应为地铁站消防安全设计的重点部位。 Based on the pedestrian traffic characteristics during e vacuation in metro, according to the risk of metro fire and its characteristic, the metro fire safety was analyzed by performance based assessment methods. After that, the Legion soft ware was used to simulate the pedestrian evacuation in fire. Two indexes were used to finish the metro fire safety assess ment,those are safe evacuation capacity and pedestrian evacua tion time. The scenario was set as fire in the train with the ex ample of double deck metro station. The calculation showed that minimum capacity of gates was the security evacuation capacity of the metro. The gate should be the key positions of the metro station fire safety design.
出处 《消防科学与技术》 CAS 北大核心 2012年第1期19-22,共4页 Fire Science and Technology
基金 国家自然科学基金资助项目(50778074) 国家重点实验室项目(2010) 华南理工大学亚热带建筑科学国家重点实验室自主研究课题项目(2010ZC17)
关键词 地铁 消防安全 人员疏散 疏散时间 动态仿真 metro fire safety pedestrian evacuation evacua tion time dynamic simulation