摘要 采用介质阻挡放电等离子体技术净化恶臭气体硫化氢。考察了电压、频率、硫化氢初始浓度以及停留时间对硫化氢净化效果的影响。结果表明,介质阻挡放电可以有效消除硫化氢污染,硫化氢净化率随电压、频率以及停留时间的增加而升高,随硫化氢初始浓度增加而下降。当电压≥19kV,频率为300Hz,停留时间为1.56s,硫化氢初始质量浓度为30.1mg/m3时,硫化氢净化率接近100%。 The dielectric barrier discharge plasma technology was applied to decompose the hydrogen sulfide so as to control malodor. The effects of voltage, frequency, initial concentration and retention time on removal efficiency of hydrogen sulfide were investigated. The results showed that hydrogen sulfide could be removed efficiently by the dielectric barrier discharge, and the removal efficiency increased with the rising of voltage, frequency and retention time, while the removal efficiency decreased with the rising of gas initial concentration. Under the operating conditions of voltage was ≥19 kV, frequency was 300 Hz, retention time was 1.56 s and inlet concentration of hydrogen sulfide was 30.1 mg/m3 , the removal efficiency of hydrogen sulfide approximated to 100%.
出处 《环境污染与防治》 CAS CSCD 北大核心 2010年第2期70-73,共4页 Environmental Pollution & Control
基金 北京工业大学校青年科研基金资助项目(No.X1005013200802) 北京工业大学博士启动基金资助项目(No.52005013200703)
关键词 等离子体 介质阻挡放电 硫化氢净化 non-thermal plasma~ dielectric barrier discharge hydrogen sulfide removal
  • 相关文献

参考文献11

二级参考文献18

  • 1J. Reece Roth and Z. Y Chen (Plasma Sciences Laboratory, Department of Electrical and Computer Engineering, University of Tennessee, Knoxville, TN 37996-2100, USA) Peter P.- Y Tsai (Textiles and Nonwovens Development Center (TANDEC), University of Tenness.TREATMENT OF METALS, POLYMER FILMS, AND FABRICS WITHA ONE ATMOSPHERE UNIFORM GLOW DISCHARGE PLASMA(OAUGDP) FOR INCREASED SURFACE ENERGY AND DIRECTIONAL ETCHING[J].Acta Metallurgica Sinica(English Letters),2001,14(6):391-407. 被引量:18
  • 2白希尧,白敏冬,依成武,付锐,满书玲,黄利群.脉冲活化一次全部治理CO_2、SO_2NO_x和烟尘研究(Ⅰ)─—分解SO_2[J].环境科学研究,1995,8(3):1-6. 被引量:12
  • 3WangRongyi, ZhangBaoan, BingSun, Ninghui Wang, Yan W'u, WeimingGong, Shuhai Liu. Apparent energy yield Of a high efficiency pulse generator with respect to S0, and NOx removal. J Electrostatics. 1995. 34: 335~ 336. 被引量:1
  • 4Masuda S. Pulse corona induced plasma chemical- process: a horzon of new plasma chemical technologies. Pure& Appl. Chem. 1988. 60(5): 727~ 731. 被引量:1
  • 5Rea M, Yank. Evaluation of pulse voltage generators. IEEE Trans. On lnd. Appl. 1995. 31(3): 507~ 512. 被引量:1
  • 6Shunsuke Hosokawa. Application of PPCP for reduction of generous pollutants exhausted from encineration plant. Proc. of NEDO Symp. On Non- thermal Discharge Plasma Technology for Air Pollution Control. 1997. 109~ 114. 被引量:1
  • 7Atkinson. R. Kinetics and mechanisms of the gas- phase reactions of thehydroxyl radical with organic compounds under atmospheric conditions. Chem. Re. 1985. 69~ 201. 被引量:1
  • 8Song Y.H.,Shin W.H.,Choi Y.S.,et al.An industrial experiment of pulse corona process for removal of SO2 and NOx from combustion flue gas.J.Adv.Oxid.Technol.,1997,2 (2):268~273 被引量:1
  • 9Kuniko Urashima,Jen-Shih Chang.Removal of volatile organic compounds from air streams and industrial flue gases by non-thermal plasma technology.IEEE Transactions on Dielectrics and Electrical Insulation,2000,7 (5):602~614 被引量:1
  • 10凌一鸣.无声放电等离子体及其应用[J].电子器件,1997,20(3):8-19. 被引量:12

共引文献91

同被引文献100

引证文献5

二级引证文献78

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部