摘要 目的:检测肺腺癌细胞内顺铂浓度,从而研究肺腺癌对顺铂的耐药与细胞内顺铂浓度的关系。方法:用四甲基偶氮唑蓝(methylthiazolyl tetrazolium,MTT)法测定 A549/DDP 细胞的耐药倍数,用 ICP-MS 测定细胞内顺铂(diammine dichloroplati-num,DDP)含量。结果:铂浓度在0.5~50μg·L^(-1)范围内线性关系良好,铂最低检出限为0.029μg·L^(-1),RSD 为0.41%~4.7%,回收率为98.2%~99.7%。耐药细胞 A549/DDP 内顺铂的浓度显著低于 A549细胞。结论:首次建立了 ICP-MS 测定细胞内顺铂浓度的方法。本方法准确、灵敏、简便,可用于测定细胞内顺铂浓度及肿瘤细胞耐顺铂的研究。 Objective: Determination of intracellular cisplatin in human lung ladenocarcinoma cell and study the relationship of drug - resistance and its content. Methods :The drug - resistance of A549/DDP to DDP was tested by MTF assay. The content of intracellular cisplatin in cell was tested by inductively coupled plasma mass spectrometry ( ICP - MS). Results :The calibration curve was linear when the concent of the Pt were in the range of 0. 5 - 50 μg·L^-1(r =0. 9997). The detection limit of Pt was 0. 029 μg·L^-1. The average rate of recovery of Pt was 98.2% -99.7% , with RSD 0.41% -4.7% (n = 5 ). The accumulation of DDP in A549/DDP were remarkably lower than these in A549 cell. Conclusion : ICP - MS determination of the content of intracellular cisplatin in human lung ladenocarcinoma cell is established for the first time. The method is accurate, sensitive and simple. It can be used for the determination of the content of intracellular cisplatin and the study of resistance of human lung ladenocarcinoma cell to cisplatin.
出处 《药物分析杂志》 CAS CSCD 北大核心 2008年第10期1609-1611,共3页 Chinese Journal of Pharmaceutical Analysis
基金 湖南省教育厅科学研究项目(NO04C432)
关键词 电感耦合等离子质谱法 细胞内顺铂浓度 耐药 inductively coupled plasma mass spectrometry concentration of intracellular cisplatin drug - resistance
  • 相关文献

参考文献4

二级参考文献31

  • 1唐东平,陈心秋.MTT法药敏试验预测卵巢癌对化经物的敏感性[J].广西医学,1996,18(6):666-667. 被引量:2
  • 2周友珍,陈惠祯,杨庆忆,刘诗权,侯汉英.人卵巢癌顺铂耐药细胞株的建立及其耐药机制的研究[J].中华医学杂志,1996,76(9):680-683. 被引量:27
  • 3刘勤,中华妇产科杂志,1998年,33卷,422页 被引量:1
  • 4王文学,第四军医大学学报,1997年,18卷,2412页 被引量:1
  • 5梁正东,中华妇产科杂志,1996年,31卷,75页 被引量:1
  • 6夏奕明,卫生研究,1987年,16卷,29页 被引量:1
  • 7Hill DM,Barnes RK,Wong HK, et al .The quantification of technetium in generator - derived pertechnetate using ICP - MS[ J ]. Appl Radiat Isot, 2000,53(3) : 415. 被引量:1
  • 8Evans EH,Wolff JC,Eckers C.Sulfur - Specific detection of impurities in cimetidine drug substance using liquid chromatography coupled to high resolution inductively coupled plasma mass spectrometry and electrospray mass speetrometry[J] .Anal Chem, 2001,73(19):4 722. 被引量:1
  • 9Axelsson BO,Jornten - Karlsson M, Miehelsen P, et al.The potential of inductively coupled plasma mass spectrometry detection for high- performance liquid chromatography combined with accurate mass measurement of organic pharmaceutical compounds[J] .Rapid Commun Mass Spectrom , 2001,15(6) : 375. 被引量:1
  • 10Baker SA,Miller-Ihli NJ .Determination of eobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry[J ]. Spectrochi Acta Part B,2000,55(15):1 823. 被引量:1

共引文献29

同被引文献8

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部