摘要 目的:探讨全程细节指导对儿童Pencatam检查患者拍图效果的影响。方法:将500例需要进行Pencatam检查的儿童分为对照组和观察组,对照组儿童按常规指导方法进行检查,观察组儿童则在检查过程中贯彻全程细节指导措施,比较两组患者反应配合度的各评价指标指数及前后表面的图像重复性和有效检查面积。结果:全程细节指导提高了患者在检查中的配合度,实验组获得有效的角膜地形图检查资料所花的时间、拍摄图片的次数均少于对照组(P<0.05),反应成像质量(QS)的各项检查指标指数均于对照组,各图像重复性的观察指标及有效检查面积均高于对照组,有统计学意义(P<0.05)。结论:全程细节指导方法可以有效提高Pencatam拍图成功率,值得临床推广应用。
出处 《中国妇幼健康研究》 2017年第S3期344-345,共2页 Chinese Journal of Woman and Child Health Research
基金 浙江省医药卫生科技计划项目2017ZH016
  • 相关文献

参考文献3

二级参考文献68

  • 1Lin N, Yee S B, Mitra S, et al. Prediction of corneal haze using an ablation depth/corneal thickness ratio after laser epithelial keratomileusis[J]. J Refract Surg, 2004, Nov-Dec ; 20 (6) :797-802. 被引量:1
  • 2Rainer G, Findl O, Pettemel V, et al. Central corneal thickness measurements with partial coherence interferom- etry, ultrasound, and the Orbscan system E J ]. Ophthal- mology, 2004, 111 (5) : 875-879. 被引量:1
  • 3Iskander N G, Penno E A, Peters N T, et al. Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [J]. J cataract Refract Surg, 2001, 27(5) :681-685. 被引量:1
  • 4Nam S M, Lee H K, Kim E K, et al. Comparison of corneal thickness after the instillation of topical anesthet- ics: proparacaine versus oxybuprocaine [J]. Cornea, 2006, 25(1) :51-54. 被引量:1
  • 5Vongthongsri A, Phusitphoykai N, Tungsiriput T. Laser in situ keratomileusis for high myopia using a small abla- tion zone and large aspheric transition zone [J]. J Cataract Refract Surg, 2004, 20( 5 Suppl) : $669-673. 被引量:1
  • 6Khoramnia R, Rabsilber T M, Auffarth G U. Central and peripheral pachymetry measurements according to age u- sing the Pentacam rotating Scheimpflug camera [J]. J Cataract Refract Surg, 2007, 33 ( 5 ) : 830-836. 被引量:1
  • 7Charles N, Charles M, Croxatto J O, et al. Surface and Orbscan II silt-scanning elevation topography in circum- scribed posterior keratoconus [ J ]. J Cataract Refract Surg, 2005, 31(3):636-639. 被引量:1
  • 8Charman W N. Mismatch between flap and stromal areas after laser in situ keratomileusis as source of flap striae[J].J Cataract Refract Surg, 2002, 28 (12) :2146- 2152. 被引量:1
  • 9Ciolino J B, Khachikian S S, Cortese M J, et al. Long- term stability of the posterior cornea after laser in situ keratomileusis[J].J Cataract Refract Surg, 2007, 33 (8) :1366-1370. 被引量:1
  • 10O' donnell C, peatability of corneas using Pentacam [J]. Maldonado-Codina C. Agreement and re- central thickness measurement in normal ultrasound pachymetry and the OCULUS Cornea, 2005, 24 (8) :920-924. 被引量:1