期刊文献+

新型眼前段分析系统测量LASIK术后角膜及前房变化 被引量:1

Measurement of the changes of cornea and anterior chamber after LASIK with new type anterior segment analysis system
原文传递
导出
摘要 目的分析Sirius新型眼前段分析系统测量LASIK术后早期角膜后表面曲率、前房深度及前房容积变化。方法前瞻性临床研究LASIK矫正近视及复性近视散光96例(96只眼),术前及术后10d行Sirius新型眼前段分析仪检查,分别记录手术前后角膜后表面曲率、前房深度及前房容积相关数据,并分析其变化。结果术后10d角膜中央3mm区角膜后表面曲率与术前相比差异无统计学意义(t=0.230,P=0.818)。而5113121及7mm区后表面曲率较术前显著增加,差异有统计学意义(t=11.316,P=0.000;t=11.615,P=0.000)。术后10d前房深度和前房容积均较术前降低,差异有统计学意义(t=19.932,P=0.000;t=6.626,P=0.000)。术前和术后角膜后表面曲率(直径3mm、5mm及7mm区)、前房深度及前房容积三者之间均无明显相关性。结论LASIK术后早期角膜后表面旁中央区较陡峭;术后早期前房变浅,前房容积变小,且手术前后角膜后表面曲率、前房深度及前房容积的变化均无明显相关性。 Objective To analyse the changes of posterior corneal curvature ( PCC ), anterior chamber depth(ACD) and anterior chamber volume(ACV) measured with Sirius anterior segment analysis system at early stage after laser in situ keratomileusis (LASIK). Methods Ninty-six eyes of 96 cases who underwent LASIK for the correction of myopia and compound myopic astigmatism in our hospital were prospectively studied. The examination with Sirius anterior segment analysis system was performed before the operation and 10 days after the operation. The changes of PCC, ACD and ACV were recorded and analyzed. Results The PCC in 5mm and 7mm zone increased significantly 10 days after the operation compared with the preoperative ones and the differences were statistically significant( t = 11. 316, P = 0. 000 ; t = 11. 615, P = 0. 000). But there was no statistically significant difference in PCC in 3ram zone between preoperation and 10 days after the operation (t = 0. 230, P = 0. 818). The ACD and ACV decreased 10 days after the operation compared with the preoperative ones and the differences were statistically significant ( t = 19. 932, P = 0. 000 ; t = 6. 626, P = 0. 000 ). There was no significant correlation among PCC, ACD and ACV. Conclusion The paracentral cornea of PCC is steep at early stage after LASIK. The ACD and ACV decrease significantly after LASIK. The changes of PCC, ACD and ACV have no significant correlation.
出处 《中华眼外伤职业眼病杂志》 2016年第2期81-85,共5页 Chinese Journal of Ocular Trauma and Occupational Eye Disease
关键词 眼前段分析系统 Sirius 角膜磨镶术 激光原位 角膜后表面曲率 前房深度 前房 容积 Anterior segment analysis system, Sirius Keratomileusis, laser in situ Corneal curvature, posterior Anterior chamber depth Anterior chamber volume
  • 相关文献

参考文献19

  • 1Nieto-Bona A,Lorente-Velazquez A, Montes-Mico R. Relationship between anterior corneal asphericity and refractive vailable [ J ].Graefes Arch Clin Exp Ophthalmol,2009,247 (6) :815-820. DOI: 10. 1007/s00417- 008-1013-2. 被引量:1
  • 2Ha BJ, Kim SW, Kim SW,et al. Pentacam and Orbscan II mea- surements of posterior corneal elevation before and after photore- fractive keratectomy[ J]. J Refract Surg, 2009, 25(3 ) :290-295. 被引量:1
  • 3Vicente D, Clinch TE, Kang PC. Changes in posterior corneal elevation after laser in situ keratomileusis enhancement[ J]. J Cata- ract Refract Surg,2008,34(5) : 785-788. DOI:10. 1016@ jcrs. 2007.12. 040. 被引量:1
  • 4Dupps WJ Jr. Biomechanical modeling of corneal ectasia [ J ]. J Refract Surg, 2005,21 ( 2 ) : 186-190. 被引量:1
  • 5侯杰,王雁,李晶,杨晓艳,张琳.准分子激光角膜屈光手术后角膜后表面非球面性变化的研究[J].中华眼科杂志,2011,47(3):223-227. 被引量:6
  • 6Yan PS, Du ZY, Wu NL, et al. Minor influence of sub-Bowman keratomileusis on the posterior corneal surface at early stage [ J ]. Curr Eye Res, 2013, 38 (8): 871- 879. DOI: 10. 3109/ 02713683.2013. 783078. 被引量:1
  • 7Smadja D,Santhiago MR,Mello GR, et al. Response of the poste- rior corneal surface to myopic laser in situ keratomileusis with di- fferent ablation depths[J]. J Cataract Refract Surg,2012,38(7 ) : 1222-1231. DOI: 10. 1016/j. jcrs. 2012.02. 044. 被引量:1
  • 8Khairat YM,Mohamed YH,Moftah IA,et al. Evaluation of corneal changes after myopic LASIK using the Pentacam[J]. Clin Ophthalmol,2013,7 : 1771-1776. DOI : 10. 2147/ OPTH. S48077. 被引量:1
  • 9Cheng AC,Ho T,Lau S, et al. Evaluation of the apparent change in posterior corneal power in eyes with LASIK using Orbscan Ⅱ with magnification compensation [ J] . J Refract Surg, 2009, 25 (2) : 221-228. 被引量:1
  • 10Ciolino JB, Belin MW. Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy [ J ]. J Cataract Refract Surg,2006,32 ( 9 ) : 1426-1431. 被引量:1

二级参考文献42

  • 1袁菁,刘磊,李新宇.准分子激光原位角膜磨镶术对瞳孔及前房深度的影响[J].临床眼科杂志,2006,14(4):300-302. 被引量:4
  • 2张艳玲,邵婷婷,施明光.正常人角膜椭球形态光学轨迹的初步验证[J].中华眼科杂志,2006,42(11):992-997. 被引量:8
  • 3郭玉峰,赵少贞,李筱荣,袁佳琴.近视眼LASIK手术对前房形态的影响[J].国际眼科杂志,2007,7(1):127-129. 被引量:4
  • 4Wegener A, Laser-Junga H. Photography of the anterior eye segment according to Scheimpflug's principle :options and limitations-a review [ J ]. Clin Experiment Ophthalmol, 2009,37 : 144-154. 被引量:1
  • 5Drews RC. Depth of field in slit lamp photography. An optical solution using the Scheimpflug principle [ J ]. Ophthalmologica, 1964,148 : 143-150. 被引量:1
  • 6Chen D,Lam AK. Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [ J ]. J Cataract Refract Surg,2007,33:448-454. 被引量:1
  • 7de Sanctis U, Missolungi A, Mutani B, et al. Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry [ J ]. Am J Ophthalmol,2007,144 : 712-718. 被引量:1
  • 8Shankar H, Taranath D, Santhirathelagan CT, et al. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements [ J ]. J Cataract Refract Surg, 2008,34 : 103-113. 被引量:1
  • 9Kawamorita T, Nakayama N, Uozato H. Repeatability and reproducibility of corneal curvature measurements using the Pentacam and Keratron topography systems[ J]. J Refract Surg,2009,25 : 539-544. 被引量:1
  • 10Labiris G, Gkika M, Katsanos A, et al. Anterior chamber volume measurements with Visante optical coherence tomography and Pentacam: repeatability and level of agreement [ J ]. Clin Experiment Ophthalmol, 2009,37 : 772-774. 被引量:1

共引文献13

同被引文献11

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部