期刊文献+

芬顿和臭氧氧化联合工艺对循环水的降解

Degradation of circulating water by the combined fenton and ozone oxidation processes
下载PDF
导出
摘要 化肥废水具有化学需氧量(COD)较高、有机物含量较低等特点,传统生物技术无法满足实际处理需求。本文研究了臭氧(O_(3))、芬顿(Fenton)和Fenton/O_(3)三种不同高级氧化工艺在不同条件(剂量,时间)下对化肥废水的COD和总有机碳(TOC)的氧化去除作用。结果表明,当Fenton/O_(3)工艺处理2 h,氧化剂量为1125.2 mg/L(Fe SO_(4)为200.0 mg/L,H_(2)O_(2)为244.2 mg/L,O_(3)为681.0 mg/L)时,TOC去除率为71.02%,COD去除率为71.28%,出水COD为13.99 mg/L,达到目标排放标准。 Chemical fertilizer wastewater has the characteristics of high COD and low organic matter content,which makes the biotechnology cannot meet the actual demand.Therefore,it is very important to study the effective technology for chemical fertilizer wastewater.In this study,the oxidation removal of O_(3),Fenton and Fenton/O_(3) on COD of three different advanced oxidation processes and TOC(dose,time)was investigated.The results show that Fenton/O_(3) process for 2 h,1125.2 mg/L is(FeSO_(4)∶200.0 mg/L;H_(2)O_(2)∶244.2 mg/L;O_(3)∶681.0 mg/L),TOC removal rate is 71.02%,COD removal rate is 71.28%,effluent COD value is 13.99mg/L.
作者 宋洪彪 许子聪 SONG Hongbiao;XU Zicong(Zhihe Environmental Technology Co.,LTD.,Zhengzhou Henan 450001;Zhihe Environmental Technology Co.,LTD.,Zhengzhou University,Zhengzhou Henan 450001)
出处 《天津化工》 CAS 2024年第6期82-85,共4页 Tianjin Chemical Industry
关键词 芬顿/臭氧氧化联合工艺 化肥废水 高级氧化工艺 Fenton/O_(3)process chemical fertilizer wastewater advanced oxidation process
  • 相关文献

参考文献3

  • 1严夏..厌氧水解-亚硝化厌氧氨氧化串联工艺处理高氨氮化肥废水的探索研究[D].北京化工大学,2016:
  • 2苏晴..电化学-微滤耦合工艺对循环水钙硬度的高效结晶与分离[D].青岛理工大学,2021:
  • 3苏荣军,王鹏,谷芳,黄丽坤.絮凝-芬顿氧化法处理制药污水的研究[J].哈尔滨商业大学学报(自然科学版),2009,25(3):292-295. 被引量:12

二级参考文献6

共引文献11