期刊文献+

LIBS结合图像筛选方法提高钢铁中Cu、Cr、Mn元素检测稳定性研究 被引量:1

Enhancement of Detection Stability for Cu,Cr and Mn in Steel by LIBS Coupled with Image Screening Methods
下载PDF
导出
摘要 优质特种钢材和低端粗钢之间的性能差异主要受其构成元素种类及其成分含量的影响,因此,如何快速准确地对物质成分进行定性及定量分析对钢铁产品的质量评估至关重要。针对传统方法难以实现对钢铁合金成分的快速准确检测的难题,采用激光诱导击穿光谱(LIBS)结合等离子体图像信息的方法,通过快速地对不同元素的特征光谱强度与激发生成的等离子体图像进行采集,分析两者之间的相关性,并通过提取的图像特征信息的异常值剔除了部分无效光谱数据,进而实现了对钢铁成分的高精度分析。通过分析延迟时间和激光能量等不同实验条件对元素特征光谱强度及其对应等离子体图像的影响规律,不仅证明了等离子体图像与光谱之间存在相关性,还利用等离子体图像特征信息的局部最优值确定了最优延迟时间、激光能量分别为1000 ns与50 mJ,并根据图像特征的平均阈值来筛选无效光谱数据。结果表明,图像筛选优化数据后,各元素谱线校准模型的决定系数(R^(2))分别从原始数据的0.978、0.986、0.957、0.935提升至0.995、0.997、0.968、0.957,且其定标曲线对未知样品元素的预测浓度相对标准偏差(RSD)下降为原始数据预测浓度RSD的50%左右。由此可知采用LIBS结合图像筛选方法可以减少定量分析的误差,提高预测结果精确度。 The performance differences between high-quality special steel and low-end crude steel are mainly influenced by the types of constituent elements and their composition levels.Therefore,how to rapidly and accurately analyze the material composition is crucial for assessing the quality of steel products.Addressing the challenge of traditional methods in achieving rapid and accurate detection of steel alloy components,this paper adopted the laser-induced breakdown spectroscopy(LIBS)combined with plasma image information.It collected the characteristic spectral intensities of different elements and the plasma images generated through rapid acquisition,analyzed the correlation between them,and removed some invalid spectral data by extracting abnormal values from the image feature information,so as to show a high-precision analysis of the steel composition.This paper,by analyzing the influence of different experimental conditions such as delay time and laser energy on the characteristic spectral intensity of elements and their corresponding plasma images,not only demonstrated the correlation between plasma images and spectra,but also determined the optimal delay time and laser energy as 1000 ns and 50 mJ based on local optimal values of image features.It further filtered out invalid spectral data based on the average threshold of image features.The results showed that after optimizing data through image filtering,the determination coefficients(R^(2))of each element spectral line calibration model improved from 0.978,0.986,0.957 and 0.935 to 0.995,0.997,0.968 and 0.957 respectively.Additionally,the relative standard deviation(RSD)of the predicted concentrations of unknown sample elements by the calibration curves decreased to about 50%of the RSD predicted by the original data.Therefore,it can be concluded that the use of LIBS combined with image filtering methods can reduce errors in quantitative analysis and improve the accuracy of prediction results.
作者 郑培超 刘少剑 王金梅 陈光辉 李刚 刘旭峰 田宏武 董大明 郭连波 ZHENG Peichao;LIU Shaojian;WANG Jinmei;CHEN Guanghui;LI Gang;LIU Xufeng;TIAN Hongwu;DONG Daming;GUO Lianbo(Chongqing Municipal Key Laboratory of Photoelectric Information Sensing and Transmission Technology,College of Optoelectronic Engineering,Chongqing University of Posts and Telecommunications,Chongqing 400065,China;Research Center of Intelligent Equipment,Beijing Academy of Agriculture and Forestry Sciences,Beijing 100097,China;Key Laboratory of Agricultural Sensors,Ministry of Agriculture and Rural Affairs,Beijing 100097,China;Wuhan National Laboratory for Optoelectronics,Huazhong University of Science and Technology,Wuhan,Hubei 430074,China)
出处 《中国无机分析化学》 CAS 北大核心 2024年第2期223-232,共10页 Chinese Journal of Inorganic Analytical Chemistry
基金 国家自然科学基金资助项目(32171627) 北京市农林科学院杰出科学家项目(JKZX202209) 重庆市教委科技项目(KJQN202000640,KJZD-M202200602) 重庆市留学人员回国创业创新支持计划项目(RC2022-56)。
关键词 光谱学 激光诱导击穿光谱 等离子体图像 定量分析 稳定性 spectroscopy laser-induced breakdown spectroscopy plasma imaging quantitative analysis stability
  • 相关文献

参考文献5

二级参考文献42

共引文献31

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部