摘要
围绕釜式重沸器,对以饱和蒸汽作为热源的重沸器及凝结水罐的安装高度进行分析。依据重沸器与精馏塔之间的压力平衡计算,结合实际工程情况,探讨了精馏塔、重沸器以及凝结水罐之间的安装高度计算方法。
In this paper,the installation height of reboiler and condensate drum with saturated steam as heat source is analyzed.According to the pressure balance calculation between the reboiler and the distillation tower,combined with the actual project,the calculation method of the installation height between the distillation tower,the reboiler and the condensate drum is discussed.
作者
陈韶华
李超群
李玉婷
Chen Shaohua;Li Chaoqun;Li Yuting(China Petroleum Engineering&Construction Corporation Southwest Company,Chengdu 610000,China)
出处
《山东化工》
CAS
2022年第20期168-170,174,共4页
Shandong Chemical Industry
关键词
釜式重沸器
重沸器
安装高度
饱和蒸汽
kettle reboiler
reboiler
installation height
saturated steam