期刊文献+

电感耦合等离子体原子发射光谱仪测定煤中锗含量标准方法的准确度研究 被引量:2

Study on Accuracy of Standard Methods for Germanium Content Determination in Coal by Inductively Coupled Plasma Atomic Emission Spectrometry
下载PDF
导出
摘要 为了确定和评估地方标准DB53/T 897-2018 《煤中锗含量的测定电感耦合等离子体原子发射光谱法》的准确度,组织了5家实验室对4个浓度水平的有证标准物质进行了协同评定试验,采用曼德尔h/k统计分析、科克伦检验、格拉布斯检验对测定结果的一致性和离群值进行了检验,建立了精密度值与样品浓度水平的函数关系,计算了重复性限、再现性限、实验室偏倚和测量方法偏倚,对正确度进行评估,结果理想;按照最新发布的ISO标准要求,进一步讨论了标准物质不确定度对正确度确定评估的影响。 In order to confirm and evaluate the accuracy of local standard DB53/T 897-2018 Determination on Germanium Content in Coal by inductively coupled plasma atomic emission spectrometry,5 labs were organized to carried out collaborative evaluation tests for certified reference standard with 4 concentration levels,Mandel h/k statistical analysis,Cochran test,Grubbs's test were adopted to verify the uniformity and outliers of testing results,the functional relationship of precision degree value and sample concentration level were established,the repeatability limits,reproducibility limits,lab bias and measurement method bias were calculated to evaluate the accuracy,the results were good.The further discussion on the effect of uncertainty of standard substance on accuracy evaluation were carried out according to requirements of newly issued ISO standard.
作者 邱烨 任艺 杨绍勇 QIU Ye;REN Yi;YANG Shao-yong(Yunnan Institute of Product Quality Supervision&Inspection,Kunming,Yunnan 650223,China;Testing Institute of No.209 Geological Team of Yunnan Nuclear Industry,Kunming,Yunnan 650000,China)
出处 《云南冶金》 2022年第3期153-159,共7页 Yunnan Metallurgy
基金 云南省地方标准制修订项目(DBZD120-2017)。
关键词 电感耦合等离子体发射光谱仪 准确度 协同评定试验 不确定度 inductively coupled plasma emission spectrometry coal germanium accuracy degree collaborative evaluation test uncertainty
  • 相关文献

参考文献7

二级参考文献42

共引文献68

同被引文献12

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部