期刊文献+

透射型辐射制冷膜对冷饮柜降温节能模拟分析

Simulation Study on Application of the Transparent Radiative-cooling Film to Beverage Coolers
下载PDF
导出
摘要 为缓解冷饮柜在制冷设备停用状态下由内部高温所引起的柜体结构损坏现象,本文通过将透射型辐射制冷膜应用于冷饮柜玻璃门外表面,利用全建筑能耗模拟软件Energyplus计算冷饮柜冷藏室内的温度与能耗。模拟计算结果表明:双层Low-e中空玻璃外表面应用透射型辐射制冷膜后,不仅降低了能耗,还缓解了内部高温问题。空载状态下冷藏室内部温度降低23.9℃,负载状态下全年空调制冷能耗降低11.6%。 In this paper,a transparent radiative-cooling film is applied to the external surface of glass doors of beverage cooler to mitigate the structural damage caused by high internal temperature when the cooling system is off.Its cooling performance is studied using a whole building energy simulation tool,Energyplus.The simulation results indicate that the application of transparent radiative-cooling film not only reduces cooling electricity consumption,but also decrease the internal air temperature.Under free-load condition,internal temperature can be lowered by 23.9℃,and under load condition,the annual electricity consumption of air-conditioning system is decreased by 11.6%.
作者 夏海宾 冯海燕 吕银燕 许伟平 徐静涛 XIA Hai-bin;FENG Hai-yan;LV Yin-yan;XU Wei-ping;XU Jing-tao(Huhang Railway Co.,Ltd.,Hangzhou 310000,China;Ningbo Ruiling Advanced Energy Materials Institute Co.,Ltd.,Ningbo 315500,China;Ningbo Ruiling Advanced Energy Technologie Co.,Ltd.,Ningbo 315500,China)
出处 《节能技术》 CAS 2021年第5期413-417,441,共6页 Energy Conservation Technology
基金 宁波市科技计划体系项目(2019B10136,2019B10137)。
关键词 冷饮柜 辐射制冷 透射膜 节能 ENERGYPLUS beverage cooler radiative-cooling transparent film energy saving EnergyPlus
  • 相关文献

参考文献6

二级参考文献12

共引文献95

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部