摘要
HZ电厂根据对前期运行人员手动20%负荷深调的数据分析,发挥主动性及创新性,实现了山西首台20%-100%全工况协调变负荷,解决了超临界机组深调过程中分离器水位控制及易转湿态的难题,为华北区域火力机组深调提供了有力的数据支撑。
Based on the data analysis of 20%manual load deep regulation by operators in the early stage,HZ power plant has realized 20%~100%coordinated variable load of the first unit in Shanxi Province,solved the problems of separator water level control and easy wet state in the process of deep regulation of supercritical units,and provided strong data support for deep regulation of thermal power units in North China.
作者
陈国震
Chen Guozhen(National Energy Group Huozhou Power Plant,Huozhou Shanxi 031413)
出处
《现代工业经济和信息化》
2021年第7期221-222,共2页
Modern Industrial Economy and Informationization
关键词
20%负荷深度调峰
炉膛水动力特性
干湿态转换
deep peak shaving at 20%load
hydrodynamic characteristics of furnace
dry wet transition