期刊文献+

3D-ASL与DSC-PWI在脑肿瘤灌注成像中的一致性分析 被引量:16

Consistency analysis between 3D arterial spin labeling and dynamic susceptibility contrast perfusion magnetic resonance imaging in perfusion imaging of brain tumor
下载PDF
导出
摘要 目的对比分析三维动脉自旋标记(3D-ASL)和动态磁敏感对比增强扫描灌注成像(DSC-PWI)在脑肿瘤灌注中脑血流量测量的一致性。方法19例脑肿瘤患者,其中胶质瘤9例,脑膜瘤5例,血管母细胞瘤2例、转移瘤2例,海绵状血管瘤1例。所有病例均经手术病理证实。术前均行常规磁共振平扫、增强扫描及3DASL和DSC-PWI灌注成像,比较19例脑肿瘤患者57个感兴趣区脑血流量(CBF)与相对脑血流量(rCBF)的差异,评价两者之间的一致性。结果3DASL所测CBF与DSC所测rCBF值两者有显著相关性(P=0.005),一致性较好。结论3D-ASL与DSC-PWI在评估脑肿瘤脑血流量方面具有一致性,3D-ASL可准确评估脑肿瘤灌注情况。 Objective To analyze the consistency between cerebral blood flow(CBF)of 3D arterial spin labeling(3D ASL)and dynamic susceptibility contrast perfusion magnetic resonance imaging(DSC-PWI)in the measurement of brain tumors.Methods Nineteen patients with pathologically confirmed brain tumors were enrolled in this study.The brain tumors included glioma(n=9),meningioma(n=5),hemangioblastoma(n=2),cerebral metastasis(n=2)and cavernous hemangioma(n=1).Both ASL and DSC MRI were performed in all the 19 patients(57 regions of interest),and CBF was quantitatively determined.Results A significant consistency was found between CBF measured by 3D ASL and the relative CBF(rCBF)determined by DSC(P=0.005).Conclusion 3D ASL and DSC PWI are consistent in evaluating blood flow in brain tumors and can accurately evaluate brain tumors perfusion.
作者 陈世林 王丽英 王莉 郑长宝 杨开志 CHEN Shilin;WANG Liying;WANG Li;ZHENG Changbao;YANG Kaizhi(Department of Radiology,Hainan Cancer Hospital,Haikou 570300,China)
出处 《南方医科大学学报》 CSCD 北大核心 2021年第8期1283-1286,共4页 Journal of Southern Medical University
基金 海南省卫计委资助项目(19A200073)。
关键词 磁共振成像 灌注 3D动脉自旋标记 动态磁敏感对比成像 脑肿瘤 magnetic resonance imaging perfusion 3D arterial spin labeling dynamic susceptibility contrast perfusion magnetic resonance imaging brain tumors
  • 相关文献

参考文献8

二级参考文献60

共引文献172

同被引文献166

引证文献16

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部