期刊文献+

刀片服务器液冷系统的设计和探究 被引量:3

Design and Exploration on Liquid Cooling System of Blade Server
下载PDF
导出
摘要 文中介绍了一种刀片服务器的液冷散热系统,对系统各部分的流量及管径进行了设计,同时通过仿真分析和实验测试来验证其散热性能。结果表明,液冷方案相比风冷方案能够将刀片内中央处理器(Central Processing Unit,CPU)支持的功率从165 W提升到300 W,采用铲齿冷板和水工质并将流量控制在1:5 L/min以下能够提高液冷系统的散热性能。最后对比分析了液冷和风冷系统的成本,液冷系统成本回收时间约为2.5年,长期运行具有良好的经济性。 A liquid cooling system of blade server is introduced in this article.The flow and the pipe diameter of various parts of the system are designed.And the performance of heat transfer is verified by simulation and experiments.The result shows that the liquid cooling solution can increase the power of the blade CPU(Central Processing Unit)from 165 W to 300 W compared with air cooling solution.And the performance of the liquid cooling system can be improved by using spade-tooth cooling plates and water refrigerant and controlling the flow below 1:5 L/min.The costs of liquid cooling and air cooling are compared.The payback time of liquid cooling system is about 2.5 years,so the liquid cooling system is more economical for long-term operation.
作者 高益兵 刘超杰 赵保周 GAO Yibing;LIU Chaojie;ZHAO Baozhou(National Key Laboratory of Mobile Network and Mobile Multimedia Technology,Shenzhen 518055,China;Zhongxing Telecommunication Equipment Corporation,Shenzhen 518055,China)
出处 《电子机械工程》 2020年第6期20-23,41,共5页 Electro-Mechanical Engineering
关键词 液冷 服务器 CPU功率 冷板 成本 liquid cooling server CPU power cooling plate cost
  • 相关文献

参考文献6

二级参考文献49

共引文献65

同被引文献48

引证文献3

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部