摘要 总氮的进一步去除是多地污水处理厂提标改造工程中的难点之一。结合污水处理厂调试期间反硝化滤池的工程实例,影响反硝化深床脱氮的因素有碳源、氧气、环境温度等,在此基础上,总结反硝化深床滤池实践运行管理控制措施,为脱氮研究及调试运行提供参考。 Total nitrogen removal is one of the difficulties in the upgrading project of wastewater treatment plants in many cities. According to engineering project experiences of denitrification deep bed filter in some wastewater treatment plants, the factors such as carbon source, oxygen and temperature can influence the nitrogen removal effect. The paper introduces operation management measures for deep bed filter in the commissioning and operation of WWTP.
作者 吕瑞滨 汪喜生 沈怡雯 赵林辉 LÜRuibin;WANG Xisheng;SHEN Yiwen;ZHAO Linhui(Shidongkou Wastewater Treatment Plant,Shanghai Chentou Wastewater Treatment Co.,Ltd.,Shanghai 200942,China;Shanghai Municipal Engneering Design Institute〈Group〉Co.,Ltd.,Shanghai 200092,China)
出处 《净水技术》 CAS 2020年第2期106-108,共3页 Water Purification Technology
关键词 反硝化深床滤池 污水处理厂 脱氮 调试运行 denitrification deep bed filter wastewater treatment plant(WWTP) denitrification commissioning and operation