期刊文献+

采用深床滤池对东港污水厂出水深度脱氮处理 被引量:6

Deep-fixed bed filtration process used for the advanced denitrification treatment of effluent from Donggang Sewage Treatment Plant
下载PDF
导出
摘要 采用深床生物滤池对东港污水处理厂的出水进行深度脱氮处理,出水DO控制在1 mg/L以下,HRT=2 h,乙酸钠投加质量浓度在0.1 g/L,经深床滤池处理后,TN可被消除40%~60%,出水实现NH3-N〈5 mg/L,TN〈15mg/L的目标。在5~15℃的低温运行区间,深床滤池仍然可以实现对TN的有效去除。 The deep-fixed bed filtration proce ss(DFB) has been applied to the advanced denitrification treatment of the effluent from Donggang Sewage Treatmeat Plant. When the DO of effluent is controlled at less than 1 mg/L,HRT=2 h,and sodium acetate=100 mg/L,40%- 60% of the TN in effluent after the treatment can be removed. The result of effluent NH3-N5 mg/L,and TN15 mg/L can be achieved. On the other hand,it is found that efficient removal can still be achieved by using the deep-fixed bed filtration process,when it runs at low temperature( 5-15 ℃).
出处 《工业水处理》 CAS CSCD 北大核心 2014年第11期66-68,共3页 Industrial Water Treatment
基金 江苏省环保科研课题(2012011)
关键词 深床滤池 脱氮 污水厂出水 deep-fixed bed filtration process denitrification effluent of sewage treatment plants
  • 相关文献

参考文献5

  • 1杨兴豹,李激,阚薇莉,赵欣萍,唐骋彪,陈宇,张超.Denite~深床反硝化滤池在污水厂升级改造中的应用[J].中国给水排水,2011,27(12):34-36. 被引量:18
  • 2孙锦宜编著..含氮废水处理技术与应用[M].北京:化学工业出版社,2003:333.
  • 3Pujol R. Process improvements for upflow submerged bio-filters [J].Water 21,2000,32(1): 25-29. 被引量:1
  • 4国家环保总局.水和废水监测分析方法[M].4版.北京:中国环境科学出版社,2002,211-213. 被引量:151
  • 5李圭白,张杰主编..水质工程学[M].北京:中国建筑工业出版社,2005:727.

二级参考文献3

共引文献167