摘要 针对我国夏热冬冷地区的气候特征,围绕外墙保温错层布置、女儿墙保温构造、窗间墙安装、穿墙套管等四种无热桥构造方式,结合传统的设计方式进行模拟及节能性能对比分析。研究结果表明:被动式围护结构无热桥技术的保温性能相比传统围护结构做法的保温性能均有所提高,其中窗间墙无热桥构造和穿墙套管无热桥构造可显著提升局部外墙的保温性能,窗间墙无热桥构造在改善外窗整体热工性能上冬季明显好于夏季,由上海和哈尔滨地区的模拟结果对比表明,在严寒地区应用被动式围护结构无热桥技术的受益更为明显。 Based on the climate characteristics in hot-summer and cold-winter zone in China,four types of building envelopes without heat bridge are simulated,including split-level arrangement of wall insulation,parapet wall insulation,exterior installation of windows and wall bushing insulation,comparing with the traditional design structure on energy saving performance. The results show that the insulation performance of passive envelope without heat bridge is superior to traditional way. Especially,the passive window and wall bushing structure can improve the insulation performance of local external wall markedly,and the passive window structure shows better thermal performance in winter. By comparing the simulation results in Shanghai and Harbin,the passive building envelope without heat bridge will be better choice in cold regions.
作者 夏麟 卢胤龙 XIA Lin;LU Yin-long(East China Architectural Design and Research Institute,Shanghai 200041,China;College of Energy and Mechanical Engineering,Shanghai University of Electric Power,Shanghai 200090,China)
出处 《建筑节能》 CAS 2019年第6期13-17,共5页 BUILDING ENERGY EFFICIENCY
基金 国家重点研发计划“基于能耗限额的长江流域热环境改善技术路径及评价”(2016YFC0700301-04)
关键词 围护结构 无热桥 热工性能 envelope without heat bridge thermal performance
  • 相关文献

参考文献1

共引文献24

同被引文献33

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部