摘要 保险粉废水有机物浓度高,可生化性差,难以处理。为了更好的改善保险粉废水的处理效果,先对保险粉废水进行预处理,采用初沉池+催化自电解+芬顿高级氧化+混凝沉淀+活性炭滤的预处理工艺处理保险粉废水,处理规模150m^3/d。工程实际运行结果表明,出水中COD去除率稳定达到了60%以上,同时废水的可生化性大大提高。 Insurance powder wastewater is difficult to treat because of its high concentration of organic matter and poor biodegradability.In order to better improve the treatment effect of powdered insurance wastewater, the powdered insurance wastewater was pretreated by the process of primary sedimentation tank + catalytic autoelectrolysis + Fenton advanced oxidation + coagulation sedimentation + activated carbon filtration, and the treatment scale was 150 m3/d.The actual operation results show that the COD removal rate in effluent is stable over 60%, and the biodegradability of wastewater is greatly improved.
作者 雷仲杰 毕可磊 冯樱艳 谭燕 王泽 Lei Zhongjie;Bi Kelei;Feng Yingyan;Tan Yan;Wang Ze(Guangzhou Sonny Environmental Protection Technology Co.,LTD,Guangdong,510663)
出处 《云南化工》 CAS 2019年第3期106-107,共2页 Yunnan Chemical Technology
关键词 铁碳微电解 保险粉废水 芬顿高级氧化 预处理 iron-carbon micro-electrolysis hydrosulfite wastewater fenton advanced oxidation pretreatment
  • 相关文献

参考文献2

二级参考文献4

  • 1高廷耀.水污染控制工程[M].北京:北京高教出版社,1993.. 被引量:4
  • 2汪大 雷乐成.水处理新技术及工程设计[M].北京:化学工业出版社,2001.83-94. 被引量:10
  • 3乌锡康.有机化工废水治理技术[M].北京:化学工业出版社,1997.. 被引量:8
  • 4张中和.给水排水设计手册[M].北京:中国建筑工业出版社,2004. 被引量:3