采用分步法测量了典型温度下填充方钴矿温差电池的匹配负载,发现填充方钴矿温差电池在470、520和580℃下热电耦合稳定的匹配负载相对于其室温内阻分别增加了约54%、66%和74%,来自于温差电池设计及串联匹配负载导致的器件高温端温度和温差增大所致。
Matched loads for a skutterudite-based thermoelectric generator were measured by a two step method under typical temperatures.It turns that when the skutterudite-based thermoelectric generator is electrical-thermal coupling stable at 470,520 and 580℃,the matched loads increase considerably as compared to the generator internal resistance at room temperature by 54%,66%and 74%,respectively.It attributes to the increase of the‘hot sides’temperature and temperature difference caused by the design of the generator and the matched loads.
作者
张骥
唐云山
李小亚
于赟
ZHANG Ji;TANG Yun-shan;LI Xiao-ya;YU Yun(School of Materials and Engineering,Jiangsu University of Technology,Changzhou Jiangsu 213001,China;Shanghai Institute of Ceramics,Chinese Academy of Sciences,Shanghai 201800,China)
出处
《电源技术》
CAS
CSCD
北大核心
2018年第7期1045-1047,共3页
Chinese Journal of Power Sources
基金
国家自然科学基金(51372261)
关键词
填充方钴矿温差电池
内阻
最大输出功率
匹配负载
skutterudite-based thermoelectric generator
internal resistance
maximum output power
matched loads