350 MW汽轮机汽动给水泵推力瓦工作面烧损原因分析 被引量:2

350 MW Steam Turbine Steam-driven Boiler Feed Water Pump Thrust Bearing Working Face Burning out Reason Analysis
下载PDF
导出
摘要 通过对汽动给水泵轴向力平衡装置原理的分析,判断某350 MW汽轮机组汽动给水泵两次推力瓦烧损原因是轴向力平衡装置间隙调整不当所造成的,将平衡装置平衡盘与平衡套之间的间隙调整后,解决了推力瓦烧损问题。 Based on the analysis of the principle of the axial force balance device of the steamdriven feed water pump,it is concluded that the cause of the two thrust tile burning of the steamfeed pump of a350MW steam turbine unit is the improper adjustment of the axial force balance de?vice.After adjusting the clearance between the balance disc and the balance sleeve,the burningproblem of thrust pad is solved.
作者 王广庭 徐万兵 王海明 WANG Guangting;XU Wanbing;WANG Haiming(State Grid Hubei Electric Power Research Institute, Wuhan Hubei 430077, China)
出处 《湖北电力》 2017年第1期38-40,共3页 Hubei Electric Power
关键词 350 MW 汽轮机组 汽动给水泵 推力瓦 烧损 350 MW steam turbine steam-driven boiler feeding water bump thrust bearing burn out
  • 相关文献

参考文献7

共引文献5

同被引文献49

引证文献2

二级引证文献4