置换通风及混合通风下室内空气环境多指标数值评价 被引量:5

Multi-indicators assessment of air environment in displacement and mixing ventilation numerical method
原文传递
导出
摘要 采用CFD数值模拟方法研究通风口位置对于置换通风与混合通风形式下室内速度场以及温度场的影响,并讨论室内PD(percentage of dissatisfied)值、垂直温差ΔT、通风效率η随通风口位置的变化规律.分析得出,办公室类房间采取混合通风模式,并将进风口位置设置于天花板右侧位置时办公室内空气环境最佳. In this paper,the CFD numerical simulation method is employed to study the influence of vent position on indoor velocity field and temperature field under displacement ventilation and mixed ventilation;and then the change rule of indoor PDvalue,vertical temperature differenceΔT,and ventilation efficiencyηwith the position of vent is discussed.It is concluded that the indoor air environment is at its best when the mixed ventilation mode is adopted in the office room with the inlet positioned on the right side of the ceiling.
作者 赵福云 程盼 张东东 ZHAO Fuyun;CHENG Pan;ZHANG Dongdong(School of Power and Mechanical Engineering,Wuhan University,Wuhan 430072,China)
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2018年第9期823-830,共8页 Engineering Journal of Wuhan University
基金 国家自然科学基金项目(编号:51778504,51208192) 湖北省杰出青年基金项目(编号:14JJ1002)
关键词 置换通风 混合通风 PD 垂直温差 通风效率 displacement ventilation mixing ventilation percentage of dissatisfied vertical temperature difference ventilation efficiency
  • 相关文献

参考文献8

二级参考文献59

  • 1邹利,高璞珍,刘秋新.国外地板辐射供暖技术特点[J].煤气与热力,2005,25(11):68-70. 被引量:2
  • 2胡建军,王汉青.厨房排风系统现状分析[J].制冷空调与电力机械,2005,26(6):53-56. 被引量:8
  • 3熊帅,汤广发,严继光,杨光.冷却顶板与独立新风相结合系统的CFD研究[J].建筑热能通风空调,2007,26(1):40-43. 被引量:8
  • 4[美]S.V.帕坦卡 郭宽良(译) 等.传热和流体流动的数值方法[M].科学技术出版社,1984.. 被引量:1
  • 5Doosam Song, Taeyeon Kim, Suwon Song, et al. Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation[J]. Applied Thermal Engineering, 2008, 28:1299-1311. 被引量:1
  • 6Jae-Han Lima, Jae-Hun Joa, Yong-Yee Kim, et al. Application of the control methods for radiant floor cooling system in residential buildings[J]. Building and Environment, 2006, 41:60-73. 被引量:1
  • 7Josephine Lau, Qingyan Chen. Energy analysis for workshops with floor-supply displacement ventilation under the U.S. climates[J]. Energy and Buildings, 2006, 38: 1212-1219. 被引量:1
  • 8Josephine Lau, Qingyan Chen. Floor-supply displacement ventilation for workshops[J]. Building and Environment, 2007, 42:1718-1730. 被引量:1
  • 9Park H, Holland D. The effect of location of a convective heat source on displacement ventilation: CFD study[J]. Building and Environment, 2001,36: 883-889. 被引量:1
  • 10王威,狄洪发,李先庭.置换通风在中国应用的可行性分析[J].南宁:全国暖通空调制冷2000年学术年会论文集,中国建筑学会暖通空调专业委员会.2000,237-240. 被引量:1

共引文献57

同被引文献38

引证文献5

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部