期刊文献+

温度和含湿量对建筑材料导热系数的影响 被引量:16

Influence of temperature and moisture content on the thermal conductivity of building materials
下载PDF
导出
摘要 导热系数是建筑材料最重要的热湿物性参数之一,温度和含湿量均能够对其产生影响。当温度和含湿量中的一个因素被确定后,一元线性函数通常被用来描述另一个因素对导热系数的影响。然而,实际情况下二者对导热系数的影响是同时存在的。采用防护热板法对聚苯乙烯泡沫(EPS)、岩棉、混凝土、胶粘剂和抹面胶等5种典型建筑材料在不同温度和含湿量下的导热系数进行测试。结果表明,对上述材料而言,二元线性函数可以用来描述温度和含湿量对导热系数的影响,且温度和含湿量之间的交互作用可以被忽略。对于EPS和岩棉等弱吸湿弱毛细材料而言,可以将二元线性函数简化为仅与温度相关的一元线性函数。 Thermal conductivity is one of the most important hygrothermal properties of building materials which depends on temperature and moisture content.The one-variable linear function is usually used to describe the influence of either temperature or moisture content on the thermal conductivity when the other one is fixed.However,for real situations temperature and moisture content have simultaneous influence.The thermal conductivities of five typical building materials-expanded polystyrene(EPS),mineral wool,concrete,adhesive mortar and rendering plaster-were measured with the guarded-hot-plate apparatus at different temperature and moisture content.Results show that the two-variable linear function is sufficient to describe the coupled influence of temperature and moisture content on all studied materials.The interaction between temperature and moisture content is negligible.For weakly hygroscopic and capillary materials such as EPS and mineral wool,the two-variable linear function can be simplified to the one-variable linear function of temperature.
出处 《土木建筑与环境工程》 CSCD 北大核心 2017年第6期123-128,共6页 Journal of Civil,Architectural & Environment Engineering
基金 国家自然科学基金(51508542) 华南理工大学亚热带建筑科学国家重点实验室开放课题(2016ZB19)~~
关键词 导热系数 温度 含湿量 建筑材料 thermal conductivity temperature moisture content building material
  • 相关文献

参考文献1

二级参考文献10

  • 1周辉,钱美丽,冯金秋,等.建筑材料热物理性能与数据手册[M].北京:中国建筑工业出版社,2010. 被引量:8
  • 2河南建材研究设计院.GB10295-1988稳态热阻及有关特性的测定-热流计法[S].北京:国家建筑材料工业局,1989:27-44. 被引量:1
  • 3河南建材研究设计院.GB10294-1988稳态热阻及有关特性的测定-防护热板法[S].北京:国家建筑材料工业局,1988:1-26. 被引量:1
  • 4CEN. EN 12664-2001 : Thermal performance of building materials and products -Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance [ S ]. 2001 : 1-74. 被引量:1
  • 5CEN. EN 12667-2001: Thermal performance of building materials and products -Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance[ S]. 2001:1-44. 被引量:1
  • 6ASTM C518: Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus[ S]. 2010 : 163-173. 被引量:1
  • 7ASTM C177: Standard Test Method for Steady-state Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-hot-plate Apparatusm S]. 2013. 被引量:1
  • 8ISO 8301:1991 (E) Thermal insulation - Determination of steady- state thermal resistance and related properties-Heat flow meterapparatus[ S ]. Switzerland, 1991 : 1-27. 被引量:1
  • 9ISO 8302:1991 (E) Thermal insulation - Determination of steady- state thermal resistance and related properties-Guarded hot plate apparatus[ S ]. Switzerland, 1991 : 1-32. 被引量:1
  • 10Feng C, Janssen H, Feng Y, building materials : Analysis reproducibility[J]. Building 172 et al. Hygric properties of porous of measurement repeatability and and Environment, 2015,85 : 160-. 被引量:1