期刊文献+

差示扫描量热分析法测定硬脂酸的凝固点 被引量:1

Determination of Solidification Point of Stearic Acid by Differential Scanning Calorimetry
下载PDF
导出
摘要 研究差示扫描量热分析(DSC)法测定硬脂酸凝固点的影响因素,对比DSC法与手工法(按GB/T 9104—2008《工业硬脂酸试验方法》进行)测定硬脂酸凝固点的异同。结果表明:DSC法测定硬脂酸凝固点的优化试验条件为样品用量10 mg,氮气流速20 m L·min^(-1),熔化温度70℃,冷却速率5℃·min^(-1);与手工法测定硬脂酸凝固点相比,DSC法操作简便、快速,试样用量小,测试精密度高和重复性好。 In this study, testing of the solidification point of stearic acid by differential scanning calorimetry ( DSC ) was investigated and testing parameters were optimized. Similarities and differences between DSC method and manual method which was according to GB/T 9104--2008, Stearic Acid Test Method were compared. The results showed that the optimal testing parameters of the DSC method were as follows: sample weight 10 mg, carrier gas flow rate 20 mL· min-1, melting temperature 70 ℃, and cooling rate 5 ℃ · min-1. Compared with manual method, DSC method was simple and fast, required only a small amount of sample, and the test presented high precision and good measurement repeatability.
作者 丁兆娟 吕延延 张艳玲 吴爱芹 刘爱芹 DING Zhaojuan LYU Yanyan ZHANG Yanling WU Aiqin LIU A iqin(Stone Testing Technology Co. , Ltd, Qingdao 266042,Chin)
出处 《橡胶科技》 2017年第1期44-46,共3页 Rubber Science and Technology
关键词 硬脂酸 凝固点 差示扫描量热分析 stearic acid solidification point differential scanning calorimetry