摘要
目的建立人尿中1-溴丙烷的顶空-气相色谱-质谱检测方法。方法准确移取4.00 m L待检尿样于15.00 m L顶空瓶中,加入质量浓度为204.200 mg/L的1-溴丁烷内标溶液20.00μL后立刻密封顶空瓶盖,于顶空装置中80℃加热平衡20.00 min,顶空瓶上方蒸气经GSBP-FFAP毛细管色谱柱(30.00 m×0.25 mm×0.25μm)分离,选择离子定量测定尿中1-溴丙烷。结果尿中1-溴丙烷在质量浓度为0.025~1.012 mg/L范围内线性关系良好,相关系数为0.999 8,方法检出限为7.5μg/L(以4.00 m L尿样计算),定量限为25.0μg/L(以4.00 m L尿样计算)。批内相对标准偏差(RSD)为2.61%~4.08%,批间RSD为2.79%~6.25%。加标回收率为99.34%~105.94%。结论本方法测定尿中1-溴丙烷灵敏度高、线性关系好、干扰少、精密度好、操作简单,适用于人尿中1-溴丙烷质量浓度的检测。
Objective To establish a detection method for 1-bromopropane in human urine by headspace gas chromatography-mass spectrometry( GC-MS). Methods A 4. 00 m L portion of the urine sample was placed in a 15. 00 m L headspace vial and 20. 00 μL of 1-bromobutane internal standard solution( 204. 200 mg / L mass concentration) was added.The bottle cap was immediately sealed. The sample was heated to 80 ℃ with an equilibrium time of 20 minutes in the headspace device. The vapor in the headspace vial was separated by GSBP-FFAP( 30. 00 m × 0. 25 mm × 0. 25 μm)capillary chromatography column and the ion was used to carry out quantitative determination of 1-bromopropane in human urine. Results The good linearity range of 1-bromopropan mass concentration was 0. 025-1. 012 mg / L, and the correlation coefficient was 0. 999 8. The detection limit was 7. 5 μg / L( urine sample volume,4. 00 m L) and the limit of quantitation was 25. 0 μg / L( urine sample volume,4. 00 m L). The relative standard deviation( RSD) of within-run precision was 2. 61%-4. 08%,and the RSD of between-run precision was 2. 79%-6. 25%. The average recovery rate was99. 34%-105. 94%. Conclusion The method of determining 1-bromopropane in human urine by headspace GC-MS has the features of high sensitivity,good linear relationship,low interference,good precision and easy operation,which is suitable for detecting 1-bromopropane mass concentration in human urine.
出处
《中国职业医学》
CAS
北大核心
2016年第3期350-353,共4页
China Occupational Medicine
基金
广东省"十二五"医学重点专科
广州市卫生局市医药卫生科技项目(20131A011096)
广州市医学重点学科建设项目
广州市职业环境与健康效应实验室建设项目(2014SY000020)