通过调研建成运营的综合管廊工作状态及其内部纳入管线的种类,分析了综合管廊内部火灾的起因和特点,介绍了综合管廊消防灭火系统常用的设计做法,并依据工程实例,阐述了超细干粉灭火系统的设计方法,以确保综合管廊的安全运营。
Through the investigation the operation and completed comprehensive pipe rack working state and its internal pipeline types, this paperanalyzed the causes and characteristics of comprehensive pipe rack internal fire, introduced the common design practice of comprehensive piperack fire extinguishing system, and based on engineering examples, elaborated the design methods of superfine powder extinguishing system, toensure the safety operation of comprehensive pipe rack.
出处
《山西建筑》
2016年第14期120-122,共3页
Shanxi Architecture
关键词
综合管廊
消防灭火系统
超细干粉灭火系统
comprehensive pipe rack, fire extinguishing system, superfine powder extinguishing system