供配电系统对综合管廊的安全运行至关重要,但目前综合管廊供电系统设计没有统一原则,各地做法也不尽相同。通过对综合管廊的功能、影响综合管廊安全运行的因素及管廊供配电系统的目标进行分析,并结合无锡太湖新城综合管廊的设计,提出以满足各防火分区能可靠完成火灾情况下各消防设备动作为原则进行供配电系统设计。
Power supply system was important and essential for safe operation of pipe gallery.But there was no uniform standard for power supply system design of pipe gallery currently.The design method was also different at everywhere.Through analysis of pipe gallery function,factors that affect the pipe gallery safe operation and the target for power supply system,a new design principle that power supply system design need meet reliable action of fire equipment in every fire prevention district in case of fire were proposed.And this design principle was also analyzed with pipe gallery of Wuxi Taihu New City.