低剂量CT技术发展及其临床应用 被引量:16

Development and clinical application of low dose computed tomography technology
下载PDF
导出
摘要 CT成像技术在临床上具有不可替代的应用价值,但由于CT扫描对患者的辐射剂量较高,因此如何在保证CT图像质量的前提下,降低对患者的辐射剂量是近年来医学影像界关注的重点,也是CT成像技术发展的一个重要方向。近年来依赖于科学技术的迅猛发展,低剂量CT技术也是日新月异,其在临床上的应用也越来越广泛。本文首先概括了传统CT检查存在的普遍问题,随后概述低剂量CT技术的发展情况,再以西门子CT为例,引入解决这些问题的低剂量CT技术,并将西门子低剂量CT技术分成3类:曝光控制技术、双源技术、图像重建技术。分别阐述它们的工作原理,最后从5个方面(胸部、颅面部、心脏冠脉、腹部和头颅)对其在临床上的应用进行了讨论。 Computed tomography (CT) imaging technology has irreplaceable value in clinical applications. But the CT scan has a higher radiation dose for patients. Recently, reducing radiation dose for patients without image quality compromise is a hot topic in medical imaging field and an important direction of CT imaging technology development. With the rapid development of science and technology, low dose CT technology develops quickly, having a wider and wider clinical application. The common problems of traditional CT examination and the developments of low dose CT technology were summarized in the paper. Based on Siemens CT, a low dose CT technology was introduced to solve the problems. The Siemens low dose CT was classified into exposure control technology, dual sources technology, and image reconstruction technology. The operating principle ofeach technology was introduced. And the clinical applications of tow dose CT for thorax, craniofacial, coronary artery, abdomen and head were analyzed.
出处 《中国医学物理学杂志》 CSCD 2016年第3期238-242,247,共6页 Chinese Journal of Medical Physics
基金 国家自然科学基金(60972122) 上海市教委科研创新重点项目(14ZZ135)
关键词 计算机断层扫描技术 低剂量 双源 辐射剂量 图像重建技术 综述 computed tomography scanning technology low dose dual sources radiation dose image reconstructiontechnology review
  • 相关文献

参考文献7

二级参考文献171

  • 1刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 2Slovis TL.CT and computed radiography:the pictures aregreat,but is the radiation dose greater than required?[J].Am JRoentgenol,2002,179(1):39-41. 被引量:1
  • 3Kalra MK,Maher MM,Toth TL,et al.Strategies for CT radiationdose optimization[J].Radiology.2004,230(3):619-628. 被引量:1
  • 4Brix G,Lechel U,Petersheim M,et al.Dynamic contrast-enhancedCT studies:balancing patient exposure and image noise[J].InvestRadiol.2011,46(1):64-70. 被引量:1
  • 5Yu L,Li H,Fletcher JG,et al.Automatic selection of tube potentialfor radiation dose reduction in CT:a general strategy[J].MedPhys,2010,37(1):234-243. 被引量:1
  • 6Kalender WA,Deak P,Kellermeier M,et al.Application-andpatient size-dependent optimization of X-ray spectra for CT[J].Med Phys,2009,36(3):993-1007. 被引量:1
  • 7Alkadhi H,Schindera ST.State of the art low-dose CTangiography of the body[J].Eur J Radiol,2011,80(1):36-40. 被引量:1
  • 8Winklehner A,Goetti R,Baumueller S,et al.Automatedattenuation-based tube potential selection for thoracoabdominalcomputed tomography angiography:improved doseeffectiveness[J].Invest Radiol,2011,46(12):767-773. 被引量:1
  • 9CAREkV(computer program).Version syngo CT 2011 A(VA40)[M].Forchheim,Germany:Siemens Healthcare,2011. 被引量:1
  • 10Alibek S,Brand M,Suess C,et al.Dose reduction in pediatriccomputed tomography with automated exposure control[J].AcadRadiol2011,Jun,18(6):690-693. 被引量:1

共引文献168

同被引文献151

引证文献16

二级引证文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部