天津某会展中心展馆区空调冷热源系统设计 被引量:4

Heating and Cooling Source of HVAC System Designed for Exhibition Area of a Conference& Exhibition Center in Tianjin
下载PDF
导出
摘要 本文针对会展建筑的特点,介绍了空调冷热源系统形式的确定,着重介绍了地埋管地源热泵、二级泵、大温差及低温热水地板辐射采暖等内容。最后,简单介绍了空调冷热源系统的运行工况。 Aiming at the characteristics of conference & exhibition building, the process of the determining of heating and cooling source of ttVAC system were introduced, including ground-source heat pump, secondary pump, large temperature difference and low temperature hot water floor radiant heating. Finally, the operating conditions of cold and heat source system were briefly present.
出处 《建筑热能通风空调》 2015年第4期87-89,26,共4页 Building Energy & Environment
关键词 会展中心 地源热泵 大温差 二级泵 exhibition center, ground-source heat pump, large temperature difference, secondary pump
  • 相关文献

参考文献8

  • 1张敏主编..中外会展业动态评估年度报告 2012[M].北京:社会科学文献出版社,2013:368.
  • 2陆耀庆主编..实用供热空调设计手册 上 第2版[M].北京:中国建筑工业出版社,2008:1439.
  • 3胡世强.新武汉火车站地源热泵系统设计[J].暖通空调,2011,41(7):80-82. 被引量:3
  • 4柴慧娟等编著..高层建筑空调设计[M].北京:中国建筑工业出版社,1995:272.
  • 5民用建筑供暖通风与空气调节设计规范(GB50736-2012)[S].北京:中国建筑工业出版社,2012. 被引量:11
  • 6公共建筑节能设计标准(GB50189-200s)[S].北京:中国建筑工业出版社,2005. 被引量:1
  • 7江连昌.大温差空调水系统的节能评价方法[J].暖通空调,2011,41(7):70-72. 被引量:8
  • 8许彩艳,陈启.不同冷凝温度下水源热泵工质性能分析[J].燃气与动力,2008,28(5):3-5. 被引量:1