摘要
本文针对会展建筑的特点,介绍了空调冷热源系统形式的确定,着重介绍了地埋管地源热泵、二级泵、大温差及低温热水地板辐射采暖等内容。最后,简单介绍了空调冷热源系统的运行工况。
Aiming at the characteristics of conference & exhibition building, the process of the determining of heating and cooling source of ttVAC system were introduced, including ground-source heat pump, secondary pump, large temperature difference and low temperature hot water floor radiant heating. Finally, the operating conditions of cold and heat source system were briefly present.
出处
《建筑热能通风空调》
2015年第4期87-89,26,共4页
Building Energy & Environment
关键词
会展中心
地源热泵
大温差
二级泵
exhibition center, ground-source heat pump, large temperature difference, secondary pump