摘要
目的:探讨FUS-100全自动尿沉渣分析仪与显微镜检测尿液有形成分的结果符合情况和影响因素。方法随机从2012年1月-2014年1月门诊尿液中抽取2000份尿液标本,分别进行全自动尿沉渣分析仪和显微镜有形成分检测,并对结果给予分析。结果FUS-100全自动尿沉渣分析仪与显微镜检测尿液成分的结果, FUS-100测试敏感,假阳性多,容易误认,霉菌会是假阴性。白细胞、红细胞、结晶、管型、滴虫差异有统计学意义(P〈0.01),只有霉菌和上皮细胞差异无无统计学意义(P〉0.05)。修饰后差异无统计学意义(P〉0.01或P>0.05)。经过修饰后, FUS-100还是非常可靠,能够为临床提供准确、有价值的化验结果。结论FUS-100尿沉渣分析仪不能代替显微镜,只能是二者有效结合,才能达到既提高工作效率又保证准确性的目的,体现其临床应用价值。
Objective To investigate corresponding results and their influence factors of FUS-100 full-automatic urinary sediment analyzer and microscope in detection of urine formed element.Methods A total of 2000 urine specimens were selected from outpatients during January, 2012-January, 2014. Urine formed element was respectively analyzed by full-automatic urinary sediment analyzer and microscope, and their results were analyzed. Results FUS-100 had strong sensitivity with false positive for easy misdiagnosis and mycete of false positive. The differences of leukocyte, erythrocyte, crystal, cast, and trichomonad had statistical significance, and only mycete and epithelial cell had no statistically significant differences (P〉0.05). After modification, their differences had no statistical significance (P〉0.01 orP〉0.05). FUS-100 with modification was reliable, and could provide acute and valuable results in clinical detection.Conclusion FUS-100 urinary sediment analyzer cannot be replacement of microscope, but their combination can provide efficient and acute work for showing their value in clinical application.
出处
《中国实用医药》
2015年第12期258-259,共2页
China Practical Medicine
关键词
全自动尿沉渣分析仪
显微镜
尿液有形成分
Full-automatic urinary sediment analyzer
Microscope
Urine formed element