期刊文献+

Comparisons in finite element analysis of minimally invasive, locking,and non-locking plates systems used in treating calcaneal fractures of Sanders type Ⅱ and type Ⅲ 被引量:12

Comparisons in finite element analysis of minimally invasive, locking,and non-locking plates systems used in treating calcaneal fractures of Sanders type Ⅱ and type Ⅲ
原文传递
导出
摘要 Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasive,locking,and non-locking plating systems used for fixing Sanders type Ⅱ and type Ⅲ calcaneal fractures.Finite element analysis was used for comparing the three types of plating systems.This study helped in guiding the clinical management of calcaneal fractures.Methods The CT data acquired from a volunteer was used to construct a finite element model of calcaneus.The fracture lines were made according to Sanders type Ⅱ (A,B,C) and type Ⅲ (AB,AC,BC) and six calcaneal fractures models were constructed accordingly.Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws,Y-size non-locking plating,and locking plating) and then fixed to these fracture models with the help of clinical principles.The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws.Then,the neutral force was applied on established methods.The displacement and presses distribution condition in various plating models were analyzed and compared.Results The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit,indicating that the three methods were suitable for application.Compared with the locked and unlocked plates,the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation.The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.Conclusions The minimally invasive plating method could be a better alternative method in treating Sanders type Ⅱ and type Ⅲ calcaneal fractures.The observed stiffness of locking plate was not obviously stronger than unlocked plate. Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasive,locking,and non-locking plating systems used for fixing Sanders type Ⅱ and type Ⅲ calcaneal fractures.Finite element analysis was used for comparing the three types of plating systems.This study helped in guiding the clinical management of calcaneal fractures.Methods The CT data acquired from a volunteer was used to construct a finite element model of calcaneus.The fracture lines were made according to Sanders type Ⅱ (A,B,C) and type Ⅲ (AB,AC,BC) and six calcaneal fractures models were constructed accordingly.Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws,Y-size non-locking plating,and locking plating) and then fixed to these fracture models with the help of clinical principles.The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws.Then,the neutral force was applied on established methods.The displacement and presses distribution condition in various plating models were analyzed and compared.Results The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit,indicating that the three methods were suitable for application.Compared with the locked and unlocked plates,the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation.The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.Conclusions The minimally invasive plating method could be a better alternative method in treating Sanders type Ⅱ and type Ⅲ calcaneal fractures.The observed stiffness of locking plate was not obviously stronger than unlocked plate.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第22期3894-3901,共8页 中华医学杂志(英文版)
关键词 calcaneal fractures Sanders type finite element analysis FIXATION minimally invasive plate calcaneal fractures Sanders type finite element analysis fixation minimally invasive plate
  • 相关文献

参考文献5

二级参考文献24

  • 1王振虎,孙辉生,彭阿钦,潘进社.跟骨骨折的临床研究[J].中国矫形外科杂志,2004,12(16):1265-1267. 被引量:44
  • 2Paprosky WG,Magnus RE.Principles of bone grafting in revision total hip arthroplasty:acetabular technique.Clin Orthop 1994; 298:147. 被引量:1
  • 3Hashemi A,Shirazi-Adl A.Finite element analysis of tibial implants—effect of fixation design and friction model.Comput Methods Biomech Biomed Engin 2000; 3:183-201. 被引量:1
  • 4Hansson S,Werke M.The implant thread as a retention element in cortical bone:the effect of thread size and thread profile:a finite element study.J Biomech 2003; 36:1247-1258. 被引量:1
  • 5Oonishi H,Isha H,Hasegawa T.Mechanical analysis of the human pelvis and its application to the articular hip joint-by means of the three dimensional finite element method.J Biomech 1983; 16:427-444. 被引量:1
  • 6Perona PG,Lawrence J,Paprosky WG,Patwardhan AG,Sartori M.Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty:an in vitro comparison of different methods of initial acetabular component fixation.J Arthroplasty 1992; 7:537-547. 被引量:1
  • 7Pilliar RM,Lee JM,Maniatopoulos C.Observations on the effect of movement on bone ingrowth into porous-surfaced implants.Clin Orthop 1986; 208:108-119. 被引量:1
  • 8Perka C,Ludwig R.Reconstruction of segmental defects during revision procedures of the acetabulum with the Burch-Schneider anti-protrusio cage.J Arthroplasty 2001; 16:568-574. 被引量:1
  • 9Yoon TR,Rowe SM,Chung JY,Song EK,Lee KB,Jung ST,et al.Acetabular revision using acetabular roof reinforcement ring with a hook.J Arthroplasty 2003; 18:746-750. 被引量:1
  • 10Pitto RP.Primary stability of acetabular reinforcement implants in revision surgery.Chir Organi Mov 1998; 83:211-219. 被引量:1

共引文献106

同被引文献61

引证文献12

二级引证文献104

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部