期刊文献+

Simultaneous determination of three curcuminoids in Curcuma longa L.by high performance liquid chromatography coupled with electrochemical detection 被引量:4

Simultaneous determination of three curcuminoids in Curcuma longa L.by high performance liquid chromatography coupled with electrochemical detection
下载PDF
导出
摘要 A novel method for analysis of three active components curcumin, demethoxycurcumin and bisdemethoxycurcumin in Curcuma longa L. was developed by HPLC coupled with electrochemical detection. Three curcuminoids were well separated on a C18 column and detected with high sensitivity. A mobile phase containing acetonitrile and 10 mM Na2HPO4-H3PO4 (pH 5.0) (50:50, v/v) was used. Good linearity was obtained in the range of 0.208-41.6, 0.197-39.4, and 0.227-114μM for curcumin, demethoxycurcumin and bisdemethoxycurcumin respectively. The limit of detection reached up to 10 ? 8 M, which was lower than that by UV detection. The relative standard deviations (RSDs) ranged from 1.06%to 1.88%for intra-day precision and from 4.30%to 5.79%for inter-day precision, respectively. The proposed method has been applied in real herb sample and recoveries ranging from 86.3%to 111%were obtained. A novel method for analysis of three active components curcumin, demethoxycurcumin and bisdemethoxycurcumin in Curcuma longa L. was developed by HPLC coupled with electrochemical detection. Three curcuminoids were well separated on a C18 column and detected with high sensitivity. A mobile phase containing acetonitrile and 10 mM Na2HPO4-H3PO4 (pH 5.0) (50:50, v/v) was used. Good linearity was obtained in the range of 0.208-41.6, 0.197-39.4, and 0.227-114μM for curcumin, demethoxycurcumin and bisdemethoxycurcumin respectively. The limit of detection reached up to 10 ? 8 M, which was lower than that by UV detection. The relative standard deviations (RSDs) ranged from 1.06%to 1.88%for intra-day precision and from 4.30%to 5.79%for inter-day precision, respectively. The proposed method has been applied in real herb sample and recoveries ranging from 86.3%to 111%were obtained.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第5期325-330,共6页 药物分析学报(英文版)
基金 supported by the National Scientific Foundation of China (Grant nos.21375101,90817103,and 30973672) Doctroral Fund of Ministry of Education of China (No.20110141110024) Innovation Seed Fund and Translational Medical Research Fund of Wuhan University School of Medicine
关键词 CURCUMIN High performance liquidchromatography Electrochemical detec- tion Curcuma longa L. Curcumin High performance liquidchromatography Electrochemical detec- tion Curcuma longa L.
  • 相关文献

参考文献2

二级参考文献9

共引文献34

同被引文献53

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部