四川广安发电有限责任公司根据机组长期低负荷运行的实际,在300 MW机组锅炉成功地尝试 了低负荷(≤55%ECR)工况下,运行单侧引、送风机的工作方式,取得了明显的经济效益。其 经验可为同类机组的运行、设计提供借鉴和参考。
Based on the actual conditions of unit's long-term low load operation in Guang 'an Power Plant, Sichuan Province, the operation mode of putting single side in duced and forced draft fans into operation under low load (≤55%ECR) has successfully been tried on the boiler of a 300MW unit, obtaining obvious economic benefits. The gained experience can provide with example and reference for units' operation and design of the same kind.