期刊文献+

温度对光纤强度特性影响的初步研究 被引量:4

Preliminary Study on the Temperature Dependence of Optical Fiber Strength
原文传递
导出
摘要 按照GB/T 15972的试验方法测试了25℃、40℃、60℃下的光纤断裂强度,试验结果表明光纤平均断裂强度随温度升高而降低,而应力腐蚀敏感性参数则出现了略微提高的现象。 The failure strength of optical fiber is tested at 25℃, 40 ℃ and 60 ℃ according to GB/T 15972 standard. The results show that the failure strength of optical fiber decrease with temperature rising, and fatigue parameter increase slightly with temperature rising.
出处 《光纤与电缆及其应用技术》 2014年第1期8-9,26,共3页 Optical Fiber & Electric Cable and Their Applications
关键词 光纤 强度 温度 optical fiber strength temperature
  • 相关文献

参考文献9

  • 1WILD G, HINCKLEY S. Acousto-ultrasonic optical fiber sensor: overview and state-of-the-art[J].IEEE Sensors Journal, 2008,8 (7) .. 1184-1193. 被引量:1
  • 2ZHANG W T, LIU Y L, LI F. Investigation on acceleration response of fiber optic mandrel hydrophone[C]// Proceedings of J Physics. 2006, 48:883-886. 被引量:1
  • 3AMES G H,MAGUIRE J M. Miniaturized mandrel- based fiber optic hydrophone[J]. J Acoust Soc Am, 2007,121 (3) :1392-1395. 被引量:1
  • 4陈炳炎著..光纤光缆的设计和制造 第2版[M].杭州:浙江大学出版社,2011:303.
  • 5DUNCAN W J, FRANCE P W, CRAIG S P. Strength of inorganic glass[M]. New York: Plenum Press, 1985:309-328. 被引量:1
  • 6MATTHEWSON M J ,KURKJIAN C R, HAINES C D, et al. Temperature dependence of strength and fatigue of fused silica fiber in the range 77 to 473 K [C]// Proceedings of SHE'2003. 2003,4940 : 74-79. 被引量:1
  • 7国家质量监督检验检疫总局.GB/T15972.30-2008机械性能的测量方法和试验程序-光纤筛选试验[S].北京:中国标准出版社,2008. 被引量:1
  • 8国家质量监督检验检疫总局.GB/T15972.31-2008机械性能的测量方法和试验程序-抗张强度[S].北京:中国标准出版社,2008. 被引量:1
  • 9国家质量监督检验检疫总局.GB/T15972.33-2008机械性能的测量方法和试验程序-应力腐蚀敏感性参数[S].北京:中国标准出版社,2008. 被引量:1