期刊文献+

潍坊地区农村住宅冬季室内热舒适调查 被引量:7

Field study on thermal comfort in rural houses in Weifang region in winter
下载PDF
导出
摘要 对57户农村住宅中86名居民的热感觉和热舒适进行了主观问卷调查,测试了室内外环境参数,对测试与调查结果进行了统计回归分析。结果表明,该地区农村住宅冬季实测热中性温度为11.9℃,预测热中性温度为14.4℃,两者相差2.5℃;居民期望温度为16.86℃;80%居民可接受的温度范围为9.9~17.5℃,可接受的最低温度明显低于城市住宅。 Surveys the thermal sensation and thermal comfort of 86 subjects in 57 rural houses by subjective questionnaires. Tests the indoor and outdoor environment parameters. Analyses the data with the statistical method. The results show that the measured thermal neutral temperature is 11. 9 ℃, the predicted thermal neutral temperature is 14.4 ℃, and there is a difference of 2.5 ℃ between them. The preferred temperature is 16.86 ℃, and the acceptable temperature range by 80 percent of residents is 9.9 - 17.5 ℃. The lowest comfort temperature in rural houses is significantly lower than that in urban houses in winter.
机构地区 南京工程学院
出处 《暖通空调》 北大核心 2013年第10期100-105,共6页 Heating Ventilating & Air Conditioning
基金 2012年度江苏省建设系统科技资助项目(编号:ZD17) 南京工程学院青年基金项目(编号:QKJB2009010)
关键词 农村住宅 热舒适 冬季 热中性温度 期望温度 现场调查 回归分析 rural house, thermal comfort, winter, thermal neutral temperature, preferred temperature, field study, regression analysis
  • 相关文献

参考文献34

  • 1ASHRAE. ASHRAE 55 - 2004 Thermal environmental conditions for human occupancy [S]. Atlanta: ASHRAE Inc, 2004. 被引量:1
  • 2ISO. International Standard 7730 Moderate themM environments:determination of PMV and PPD indices and specification of the conditions for thermal comfort [ S ]. Geneva: International Organization for Standardization, 2005. 被引量:1
  • 3Schiller G E, A comparison of measured and predicted comfort in Office buildings[G]///ASHRAE Trans, 1990,96 (1) : 609- 622. 被引量:1
  • 4de Dear R J, Fountain M E. Field experiments on occupant comfort and office thermal environments in a hot-humid climate[G]//ASHRAE Trans, 1994,100 (2) ~457-475. 被引量:1
  • 5Donnini G, Molina J, Martello C,et al. Field study of occupant comfort and office thermal environments in a cold Climate[G]// ASHRAE Trans, 1996,102(2): 795- 802. 被引量:1
  • 6Cena K, de Dear R J. Field study of occupant comfort and office thermal environments in a hot arid climate [G]//ASHRAE Trans, 1999,105 (2) : 204- 217. 被引量:1
  • 7Tao P. The thermal sensation difference between Chinese and American people [C]//Indoor Air'90: The 5th International Conference on Indoor Air Quality and Climate. Ottawa, ON, Canada: Canada Mortgage and Housing Corporation, 1990 : 699- 704. 被引量:1
  • 8Nicol J F, Raja I A, Allaudin A, et al. Climatic variation in comfortable temperatures: the Pakistan projects [ J ]. Energy and Buildings, 1999, 30 ( 3 ) : 261-279. 被引量:1
  • 9de Dear R J, Auliciems A. A validation of the predicted mean vote model of thermal comfort in six Australian field studies[G]//ASHRAE Trans, 1985, 91(2b) :452- 468. 被引量:1
  • 10Oseland N A. Acceptable temperature ranges in naturally ventilated and air-conditioned offices[G]// ASHRAE Trans, 1998,104(2) : 1018-1036. 被引量:1

二级参考文献89

共引文献317

同被引文献70

引证文献7

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部