期刊文献+

发电厂水冷壁管腐蚀失效分析 被引量:9

Corrosion failure analysis on water-cooled wall tubes of power station
下载PDF
导出
摘要 针对发电厂锅炉水冷壁管内表面腐蚀坑的成因进行了失效分析。通过微观形貌观察、扫描电镜及能谱仪分析和X射线衍射等手段确定腐蚀产物为Fe3O4;对水冷壁管各典型部位的化学成分(包括残余元素量)、显微组织、晶粒度、非金属夹杂物、脱碳层进行分析,排除引起腐蚀失效的内部因素;通过锅炉水质的碱度、pH值等检测记录,综合分析表明:炉水碱度偏高导致水冷壁内表面发生碱腐蚀反应,即碱腐蚀失效。 Failure analysis was carried out to find out the causes of eorrosion pits on the inner surface of boiler water-cooled wall tubes of power station. The corrosion product Fe304 was confirmed by microstructural observation, SEM and EDS and X-ray diffraction; the typical parts of water-cooled wall tube were analyzed, including chemical composition (the amount of residual elements), microstructure, grain size, nonmetallic inclusions, decarburized layer. According to the results, it is excluded that internal factors may cause corrosion failure. By analyzing testing records of alkalinity and pH value of boiler water, it is fnund that the high alkalinity of boiler water results in alkali corrosion reaction.
出处 《兵器材料科学与工程》 CSCD 北大核心 2013年第2期119-122,共4页 Ordnance Material Science and Engineering
关键词 水冷壁管 腐蚀 失效分析 碱度 碱腐蚀 water-cooled wall tubes corrosion failure analysis alkalinity alkali corrosion
  • 相关文献

参考文献6

  • 1张栋等编著..失效分析[M].北京:国防工业出版社,2004:488.
  • 2徐洪.高压锅炉水冷壁管失效分析[J].中国腐蚀与防护学报,2003,23(5):312-315. 被引量:6
  • 3徐洪.高压锅炉水冷壁管碱腐蚀诊断与机理研究[J].中国电机工程学报,2003,23(2):183-187. 被引量:30
  • 4赵志农.腐蚀失效分析案例[M].北京:化学工业出版社,2008.213-229. 被引量:5
  • 5周昕主编,湖南省电机工程学会编著..火力发电厂锅炉受热面失效分析与防护[M].北京:中国电力出版社,2004:231.
  • 6中国腐蚀与防护学会《金属防腐蚀手册》编写组编..金属防腐蚀手册[M].上海:上海科学技术出版社,1989:501.

二级参考文献4

共引文献36

同被引文献80

引证文献9

二级引证文献14